Table 7. Service Processor Error Codes (continued)
Error Code Description
4508 245C Memory system and other bus processor
runtime diagnostics detected 2W 2M
processor fault
4508 245D Memory system and other bus processor
runtime diagnostics detected 4W 4M
processor fault
4508 248B Memory system and other bus processor
runtime diagnostics detected primary I/O
drawer operator panel fault
4508 24A5 Memory system and other bus processor
runtime diagnostics detected 2W 500 MHz
processor fault
4508 24A6 Memory system and other bus processor
runtime diagnostics detected 4W 500 MHz
processor fault
4508 25AB Memory system and other bus processor
runtime diagnostics detected 400 MHz clock
fault
4508 25AD Memory system and other bus processor
runtime diagnostics detected 540 MHz clock
fault
4508 25B1 Memory system and other bus processor
runtime diagnostics detected 750 MHz clock
fault
4508 25B3 Memory system and other bus processor
runtime diagnostics detected 4W 750 MHz
processor fault
4508 25B4 Memory system and other bus processor
runtime diagnostics detected 2W 750 MHz
processor fault
4508 25DA Memory system and other bus processor
runtime diagnostics detected 500 MHz clock
fault
4508 267D Memory system and other bus processor
runtime diagnostics detected an 8W, 750
MHz regulator fault
4508 2687 Memory system and other bus processor
runtime diagnostics detected remote I/O bus
adapter fault
4508 271A Memory system and other bus processor
runtime diagnostics detected primary I/O
planar fault
4508 271D Memory system and other bus processor
runtime diagnostics detected secondary I/O
planar fault
4508 2733 Memory system and other bus processor
runtime diagnostics detected I/O clock fault
Action/
Possible Failing FRU
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2d
Operator Panel
Location: U0.1-L1
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2d
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2d
400 MHz clock
Location: U1.1-P1.1.1
540 MHz clock
Location: U1.1-P1.1.1
540 MHz clock
Location: U1.1-P1.1.1
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
750 MHz clock
Location: U1.1-P1.1.1
8W regulator card
Location: U1.1-P1-V1
Remote I/O bus adapter
Location: U0.1-P1.1
Primary I/O planar
Location: U0.1-P1
Secondary I/O planar
Locations: U0.2-P1
U0.3-P1
U0.4-P1
CEC RIO bus adapter
Location: U1.1-P1.1
Chapter 5. Error Code to FRU Index