IBM RS/6000 Enterprise Server M80 Service Manual page 220

Hide thumbs Also See for RS/6000 Enterprise Server M80:
Table of Contents

Advertisement

Table 6. Firmware Error Codes. (continued)
Error Code Description
2201 1001 PCI token ring adapter
Adapter failed to complete hardware
initialization.
25A0 0001 Cache L2 controller failure
25A1 0001 Cache L2 SRAM failure
25A8 0xxx NVRAM problems
25A8 0000 Initialization failed, device test failed
25A8 0001 Init-NVRAM invoked, all of NVRAM initialized Refer to Action under error code 25A80xxx.
25A8 0002 Init-NVRAM invoked, some data partitions
may have been preserved.
25A8 0011 Data corruption detected, all of NVRAM
initialized
25A8 0012 Data corruption detected, some data
partitions may have been preserved.
25A8 0100 NVRAM data validation check failed.
25A8 0201 Unable to expand target partition - Saving
configuration variable.
25A8 0202 Unable to expand target partition - Writing
error log entry.
25A8 0203 Unable to expand target partition - Writing
VPD data.
25A8 0210 Setenv/$Setenv parameter error - name
contains a null character.
202
Service Guide
Action/
Possible Failing FRU
Replace the Adapter
See "Determining Location Code" on page
160 for location code information related to
this error.
1. Replace the processor card.
See "Determining Location Code" on
page 160 for processor card location
information.
2. Replace the CEC backplane.
Location: U1.1-P1.
1. Replace the processor card.
See "Determining Location Code" on
page 160 for processor card location
information.
Errors reported against NVRAM can be
caused by low battery voltage and (more
rarely) power outages that occur during
normal system usage. With the exception of
the 25A80000 error, these errors are
warnings that the NVRAM data content had
to be reestablished and do not require any
FRU replacement unless the error is
persistent. When one of these errors occurs,
any system customization (for example, boot
device list) information has been lost, the
system may need to be reconfigured.
If the error is persistent, replace primary I/O
drawer backplane
Location: U0.1-P1
Refer to Action under error code 25A80xxx.
Refer to Action under error code 25A80xxx.
Refer to Action under error code 25A80xxx.
Refer to Action under error code 25A80xxx.
Turn off, turn on system unit and retry the
operation before replacing any system
component.
Refer to Action under error code 25A80xxx.
Refer to Action under error code 25A80xxx.
Refer to Action under error code 25A80xxx.
Refer to Action under error code 25A80xxx.
Refer to Action under error code 25A80xxx.