Table 7. Service Processor Error Codes (continued)
Error Code Description
406E 3284 Scan control routines detected PCI controller
PHB0
406E 3285 Scan control routines detected PCI controller
PHB1
406E 3286 Scan control routines detected PCI controller
PHB2
406F 0001 Error code generation/logging detected CEC
backplane failure
406F 0003 Error code generation/logging detected
processor fault
406F 0009 Error code generation/logging detected
memory fault
406F 00A0 Error code generation/logging detected CSP
service processor firmware fault
406F 00A1 Error code generation/logging detected AIX or
system firmware fault
406F 00A2 Error code generation/logging detected
service processor firmware (processor
runtime diagnostics) fault
406F 00A3 Error code generation/logging detected
memory plugging fault
406F 00A4 Error code generation/logging detected
application caused fault
406F 00A5 Error code generation/logging detected
invalid system configuration
406F 00A6 Error code generation/logging detected no
usable memory
406F 00A7 Error code generation/logging detected
hardware problem
406F 00B0 Error code generation/logging detected bus
controller lock-unlock failure
406F 00B1 Error code generation/logging detected bus
controller failure
Action/
Possible Failing FRU
1. RIO bus adapter
Location: U0.1-P1.1
2. Primary I/O drawer backplane
Location: U0.1-P1
1. RIO bus adapter
Location: U0.1-P1.1
2. Primary I/O drawer backplane
Location: U0.1-P1
1. RIO bus adapter
Location: U0.1-P1.1
2. Primary I/O drawer backplane
Location: U0.1-P1
CEC backplane
Location: U1.1-P1
All processors
Location: U1.1-P1-C1
All memory
Location: U1.1-P1-M1 x2
Update system firmware
Location: U0.1-P1/Y1
1. Check for AIX updates
2. Check for system firmware updates
Location: U0.1-P1/Y1
Check for system firmware updates
Location: U0.1-P1/Y1
All pluggable memory
Application software
Verify system components are supported and
properly installed.
1. Ensure that CEC memory is properly
installed.
2. If more than one DIMM is called out, go
to the service processor Memory
Configuration/Deconfiguration Menu to
verify memory DIMMs state. See
"Memory Configuration/Deconfiguration
Menu" on page 374 for more information.
Go to minimum configuration and also run
CEC minimum configuration
RIO bus adapter
Location: U0.1-P1.1
RIO bus adapter
Location: U0.1-P1.1
Chapter 5. Error Code to FRU Index