IBM RS/6000 Enterprise Server M80 Service Manual page 353

Hide thumbs Also See for RS/6000 Enterprise Server M80:
Table of Contents

Advertisement

Table 7. Service Processor Error Codes (continued)
Error Code Description
4B2F 271A Processor system and error code detected
primary I/O planar fault
4B2F 271D Processor system and error code detected
secondary I/O planar fault
4B2F 2733 Processor system and error code detected
I/O clock fault
4B2F 27AA Processor system and error code detected a
2W/4W regulator fault
4B2F 27AB Processor system and error code detected an
8W regulator fault
4B2F 281C Processor system and error code detected
CEC backplane fault
4B2F 281D Processor system and error code detected
Model 6M1 CEC backplane fault
4B2F 285D Processor system and error code detected
SPCN fan controller fault
4B2F 288A Processor system and error code detected
memory riser card fault
4B2F 300A Processor system and error code detected 32
MB DIMM fault
4B2F 300B Processor system and error code detected
128 MB DIMM fault
4B2F 300C Processor system and error code detected
256 MB DIMM fault
4B2F 300D Processor system and error code detected
512 MB (stacked) DIMM fault
4B2F 300E Processor system and error code detected
512 MB (unstacked) DIMM fault
4B2F 301F Processor system and error code detected
128 MB DIMM fault
4B2F 303A Processor system and error code detected 1
GB DIMM fault
Action/
Possible Failing FRU
Primary I/O planar
Location: U0.1-P1
Secondary I/O planar
Locations: U0.2-P1
U0.3-P1
U0.4-P1
CEC RIO bus adapter
Location: U1.1-P1.1
2W/4W regulator card
Location: U1.1-P1-V1
8W regulator card
Location: U1.1-P1-V1
CEC backplane
Location: U1.1-P1
CEC backplane
Location: U1.1-P1
1. SPCN fan controller
Location: U0.1-X2
2. I/O drawer power distribution board
Location: U0.1-X1
1. Go to the service processor Memory
Configuration/Deconfiguration Menu to
verify memory DIMMs state. See
"Memory Configuration/Deconfiguration
Menu" on page 374 for more information.
2. Memory riser card
Locations: U1.1-P1-M1
U1.1-P1-M2
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Chapter 5. Error Code to FRU Index
335

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eserver pseries 660 6m1

Table of Contents