IBM RS/6000 Enterprise Server M80 Service Manual page 339

Hide thumbs Also See for RS/6000 Enterprise Server M80:
Table of Contents

Advertisement

Table 7. Service Processor Error Codes (continued)
Error Code Description
4B28 245C Processor system and other bus processor
runtime diagnostics detected 2W 2M
processor fault
4B28 245D Processor system and other bus processor
runtime diagnostics detected 4W 4M
processor fault
4B28 248B Processor system and other bus processor
runtime diagnostics detected primary I/O
drawer operator panel fault
4B28 24A5 Processor system and other bus processor
runtime diagnostics detected 2W 500 MHz
processor fault
4B28 24A6 Processor system and other bus processor
runtime diagnostics detected 4W 500 MHz
processor fault
4B28 25AB Processor system and other bus processor
runtime diagnostics detected 400 MHz clock
fault
4B28 25AD Processor system and other bus processor
runtime diagnostics detected 540 MHz clock
fault
4B28 25B1 Processor system and other bus processor
runtime diagnostics detected 750 MHz clock
fault
4B28 25B3 Processor system and other bus processor
runtime diagnostics detected 4W 750 MHz
processor fault
4B28 25B4 Processor system and other bus processor
runtime diagnostics detected 2W 750 MHz
processor fault
4B28 25DA Processor system and other bus processor
runtime diagnostics detected 500 MHz clock
fault
4B28 267D Processor system and other bus processor
runtime diagnostics detected an 8W, 750
MHz regulator fault
4B28 2687 Processor system and other bus processor
runtime diagnostics detected remote I/O bus
adapter fault
4B28 271A Processor system and other bus processor
runtime diagnostics detected primary I/O
planar fault
4B28 271D Processor system and other bus processor
runtime diagnostics detected secondary I/O
planar fault
4B28 2733 Processor system and other bus processor
runtime diagnostics detected I/O clock fault
Action/
Possible Failing FRU
Go to "MAP 1540: Minimum Configuration"
on page 110.
Go to "MAP 1540: Minimum Configuration"
on page 110.
Operator Panel
Location: U0.1-L1
Go to "MAP 1540: Minimum Configuration"
on page 110.
Go to "MAP 1540: Minimum Configuration"
on page 110.
400 MHz clock
Location: U1.1-P1.1.1
540 MHz clock
Location: U1.1-P1.1.1
750 MHz clock
Location: U1.1-P1.1.1
Go to "MAP 1540: Minimum Configuration"
on page 110.
Go to "MAP 1540: Minimum Configuration"
on page 110.
500 MHz clock
Location: U1.1-P1.1.1
8W regulator card
Location: U1.1-P1-V1
Remote I/O bus adapter
Location: U1.1-P1.1
Primary I/O planar
Location: U0.1-P1
Secondary I/O planar
Locations: U0.2-P1
U0.3-P1
U0.4-P1
CEC RIO bus adapter
Location: U1.1-P1.1
Chapter 5. Error Code to FRU Index
321