Table 7. Service Processor Error Codes (continued)
Error Code Description
4508 51AC Memory system and other bus processor
runtime diagnostics detected 595W ac power
supply fault
4508 51AD Memory system and other bus processor
runtime diagnostics detected 595W dc power
supply fault
4508 51AE Memory system and other bus processor
runtime diagnostics detected 1100W dc
power supply fault
4509 245B Memory system and memory test detected
2W 4M processor fault
4509 245C Memory system and memory test detected
2W 2M processor fault
4509 245D Memory system and memory test detected
4W 4M processor fault
4509 248B Memory system and memory test detected
primary I/O drawer operator panel fault
4509 24A5 Memory system and memory test detected
2W 500 MHz processor fault
4509 24A6 Memory system and memory test detected
4W 500 MHz processor fault
4509 25AB Memory system and memory test detected
400 MHz clock fault
4509 25AD Memory system and memory test detected
540 MHz clock fault
4509 25B1 Memory system and memory test detected
750 MHz clock fault
4509 25B3 Memory system and memory test detected
4W 750 MHz processor fault
4509 25B4 Memory system and memory test detected
2W 750 MHz processor fault
4509 25DA Memory system and memory test detected
500 MHz clock fault
4509 267D Memory system and memory test detected
an 8W, 750 MHz regulator fault
4509 2687 Memory system and memory test detected
remote I/O bus adapter fault
4509 271A Memory system and memory test detected
primary I/O planar fault
Action/
Possible Failing FRU
595W ac power supply
Locations: U0.1-V1
U0.1-V2
595W dc power supply
Locations: U0.1-V1
U0.1-V2
1100W dc power supply
Locations: U1.1-V1
U1.1-V2
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
Operator Panel
Location: U0.1-L1
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
400 MHz clock
Location: U1.1-P1.1.1
540 MHz clock
Location: U1.1-P1.1.1
750 MHz clock
Location: U1.1-P1.1.1
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
500 MHz clock
Location: U1.1-P1.1.1
8W regulator card
Location: U1.1-P1-V1
Remote I/O bus adapter
Location: U0.1-P1.1
Primary I/O planar
Location: U0.1-P1
Chapter 5. Error Code to FRU Index