Table 7. Service Processor Error Codes (continued)
Error Code Description
4069 022D Memory test detected memory DIMM group
fault
4069 022E Memory test detected memory DIMM group
pair A fault
4069 022F Memory test detected memory DIMM group
fault
4069 0231 Memory test detected memory DIMM fault
4069 0232 Memory test detected memory DIMM fault
4069 0233 Memory test detected memory DIMM fault
4069 0234 Memory test detected memory DIMM fault
4069 0235 Memory test detected memory DIMM fault
4069 0236 Memory test detected memory DIMM fault
4069 0237 Memory test detected memory DIMM fault
4069 0238 Memory test detected memory DIMM fault
4069 023D Memory test detected memory DIMM group
fault
4069 023E Memory test detected memory DIMM group
fault
4069 023F Memory test detected memory DIMM group
fault
4069 02FF Memory test detected memory on riser fault
4069 0300 Memory test detected processor card fault
4069 0400 Memory test detected processor card fault
4069 0500 Memory test detected memory riser card fault Memory riser card 2
4069 0501 Memory test detected memory DIMM fault
4069 0502 Memory test detected memory DIMM fault
4069 0503 Memory test detected memory DIMM fault
Action/
Possible Failing FRU
Memory octal C, riser 1
Locations: U1.1-P1-M1.5 x8
Memory quad C odd, riser 1
Locations: U1.1-P1-M1.5 x4
Memory quad C even, riser 1
Locations: U1.1-P1-M1.6 x4
Memory DIMM 7, riser 1
Location: U1.1-P1-M1.7
Memory DIMM 8, riser 1
Location: U1.1-P1-M1.8
Memory DIMM 15, riser 1
Location: U1.1-P1-M1.15
Memory DIMM 16, riser 1
Location: U1.1-P1-M1.16
Memory DIMM 23, riser 1
Location: U1.1-P1-M1.23
Memory DIMM 24, riser 1
Location: U1.1-P1-M1.24
Memory DIMM 31, riser 1
Location: U1.1-P1-M1.31
Memory DIMM 32, riser 1
Location: U1.1-P1-M1.32
Memory octal D, riser 1
Location: U1.1-P1-M1.7 x8
Memory quad D odd, riser 1
Location: U1.1-P1-M1.7 x4
Memory quad D even, riser 1
Location: U1.1-P1-M1.8 x4
All memory on riser 1
Location: U1.1-P1-M1.1 x32
Memory failure on riser card 1 that cannot be
automatically isolated. go to "MAP 1540:
Minimum Configuration" on page 110 and run
CEC drawer minimum configuration for
further isolation.
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C2
Location: U1.1-P1-M1
Memory DIMM 1, riser 2
Location: U1.1-P1-M2.1
Memory DIMM 2, riser 2
Location: U1.1-P1-M2.2
Memory DIMM 9, riser 2
Location: U1.1-P1-M2.9
Chapter 5. Error Code to FRU Index
231

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eserver pseries 660 6m1

Table of Contents