Table 7. Service Processor Error Codes (continued)
Error Code Description
4069 00A2 Memory test detected service processor
firmware (processor runtime diagnostics) fault
4069 00A3 Memory test detected memory plugging fault
4069 00A4 Memory test detected application caused
fault
4069 00A5 Memory test detected invalid system
configuration
4069 00A6 Memory test detected no usable memory
4069 00A7 Memory test detected hardware problem
4069 00B0 Memory test detected bus controller
lock-unlock failure
4069 00B1 Memory test detected bus controller failure
4069 00B3 Memory test detected clock fault
4069 00B7 Memory test detected insufficient hardware
resources to continue IPL
4069 0200 Memory test detected memory riser card fault Memory riser card 1
4069 0201 Memory test detected memory DIMM fault
4069 0202 Memory test detected memory DIMM fault
4069 0203 Memory test detected memory DIMM fault
4069 0204 Memory test detected memory DIMM fault
4069 0205 Memory test detected memory DIMM fault
4069 0206 Memory test detected memory DIMM fault
4069 0207 Memory test detected memory DIMM fault
Action/
Possible Failing FRU
Check for system firmware updates
Location: U0.1-P1/Y1
All pluggable memory
Application software
Verify system components are supported and
properly installed.
1. Ensure that CEC memory is properly
installed.
2. If more than one DIMM is called out, go
to the service processor Memory
Configuration/Deconfiguration Menu to
verify memory DIMMs state. See
"Memory Configuration/Deconfiguration
Menu" on page 374 for more information.
Go to minimum configuration and also run
CEC minimum configuration
RIO bus adapter
Location: U0.1-P1.1
RIO bus adapter
Location: U0.1-P1.1
1. Clock card
Location: U1.1-P1.1.1
2. CEC RIO bus adapter
Location: U1.1-P1.1
This error code appears after the initial
testing by the service processor firmware on
the CEC was completed correctly, but a
problem occurred when the firmware tried to
communicate outside the CEC. Suspect a
problem with the RIO interface, either cables
or adapters.
Location: U1.1-P1-M1
Memory DIMM 1, riser 1
Location: U1.1-P1-M1.1
Memory DIMM 2, riser 1
Location: U1.1-P1-M1.2
Memory DIMM 9, riser 1
Location: U1.1-P1-M1.9
Memory DIMM 10, riser 1
Location: U1.1-P1-M1.10
Memory DIMM 17, riser 1
Location: U1.1-P1-M1.17
Memory DIMM 18, riser 1
Location: U1.1-P1-M1.18
Memory DIMM 25, riser 1
Location: U1.1-P1-M1.25
Chapter 5. Error Code to FRU Index