Table 7. Service Processor Error Codes (continued)
Error Code Description
4068 0534 Other bus processor runtime diagnostics
detected memory DIMM fault
4068 0535 Other bus processor runtime diagnostics
detected memory DIMM fault
4068 0536 Other bus processor runtime diagnostics
detected memory DIMM fault
4068 0537 Other bus processor runtime diagnostics
detected memory DIMM fault
4068 0538 Other bus processor runtime diagnostics
detected memory DIMM fault
4068 053D Other bus processor runtime diagnostics
detected memory DIMM group fault
4068 053E Other bus processor runtime diagnostics
detected memory DIMM group fault
4068 053F Other bus processor runtime diagnostics
detected memory DIMM group fault
4068 05FF Other bus processor runtime diagnostics
detected memory on riser fault
4068 0600 Other bus processor runtime diagnostics
detected CEC RIO bus adapter
4068 0601 Other bus processor runtime diagnostics
detected clock card fault
4068 3101 Other bus processor runtime diagnostics
detected RIO port 0 fault
4068 3102 Other bus processor runtime diagnostics
detected RIO port 1 fault
4068 3103 Other bus processor runtime diagnostics
detected RIO port 2 fault
4068 3104 Other bus processor runtime diagnostics
detected RIO port 3 fault
4068 3121 Other bus processor runtime diagnostics
detected RIO cable on port 0 fault
4068 3122 Other bus processor runtime diagnostics
detected RIO cable on port 1 fault
4068 3123 Other bus processor runtime diagnostics
detected RIO cable on port 2 fault
Action/
Possible Failing FRU
Memory DIMM 16, riser 2
Location: U1.1-P1-M2.16
Memory DIMM 23, riser 2
Location: U1.1-P1-M2.23
Memory DIMM 24, riser 2
Location: U1.1-P1-M2.24
Memory DIMM 31, riser 2
Location: U1.1-P1-M2.31
Memory DIMM 32, riser 2
Location: U1.1-P1-M2.32
Memory octal D, riser 2
Location: U1.1-P1-M2.7 x8
Memory quad D odd, riser 2
Location: U1.1-P1-M2.7 x4
Memory quad D even, riser 2
Location: U1.1-P1-M2.8 x4
Memory failure on riser card 2 that cannot be
automatically isolated. go to "MAP 1540:
Minimum Configuration" on page 110 and run
CEC drawer minimum configuration for
further isolation.
CEC RIO bus adapter
Location: U1.1-P1.1
CEC clock card
Location: U1.1-P1.1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 0
Location: U1.1-P1.1/Q1
2. CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 1
Location: U1.1-P1.1/Q2
2. CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 2
Location: U1.1-P1.1/Q3
2. CEC RIO bus adapter
Location: U1.1-P1.1
Chapter 5. Error Code to FRU Index
227