IBM RS/6000 Enterprise Server M80 Service Manual page 210

Hide thumbs Also See for RS/6000 Enterprise Server M80:
Table of Contents

Advertisement

Table 5. SPCN Error Codes (continued)
Error Code Description
1041 840E SPCN default configuration loaded
1041 840F I/O type not recognized
1041 8A00 A different I/O drawer is connected to the
CEC
1041 9012 Invalid address
1041 9013 Invalid address
1041 9014 Invalid address mode
1041 9021 SPCN temporary internal error
1041 9022 Secondary I/O drawer not present
1041 9023 Secondary I/O drawer is present but off
1041 902D Secondary I/O drawer not present
1041 9038 I/O drawer node fault
1041 9039 I/O drawer node fault
1041 9042 EEPROM failure
1041 9043 Download failure
1041 9046 QDS packet sequence error
1041 9047 QDS block sequence error
1041 9080 Undefined status code received
192
Service Guide
Action/
Possible Failing FRU
1. Check cabling
2. From the main service processor menu,
select the System Information Menu,
then select the Power Control Network
Utilities Menu. Use option three to set
the I/O type to 84. Reboot the system.
3. Primary I/O drawer backplane
Location: U0.1-P1
1. Check cabling
2. From the main service processor menu,
select the System Information Menu,
then select the Power Control Network
Utilities Menu. Use option three to set
the I/O type to 84. Reboot the system.
3. Primary I/O drawer backplane
Location: U0.1-P1
Informational only
1. Check SPCN cabling
2. Secondary I/O Backplane
Location: U0.2-P1
1. Check SPCN cabling
2. Secondary I/O Backplane
Location: U0.2-P1
Update system firmware
Location: U0.1-P1/Y1
Note: Allow up to 30 minutes for this update
to take effect.
Information only
Check cabling
Information only
Information only
Secondary I/O backplane
Location: U0.4-P1
Secondary I/O backplane
Location: U0.4-P1
Secondary I/O backplane
Location: U0.4-P1
1. Check for system firmware update
2. Call second level of support
1. Check for system firmware update
2. Call second level of support
1. Check for system firmware update
2. Call second level of support
Secondary I/O backplane
Location: U0.4-P1