Table 7. Service Processor Error Codes (continued)
Error Code Description
406F 0513 Error code generation/logging detected
memory DIMM fault
406F 0514 Error code generation/logging detected
memory DIMM fault
406F 0515 Error code generation/logging detected
memory DIMM fault
406F 0516 Error code generation/logging detected
memory DIMM fault
406F 0517 Error code generation/logging detected
memory DIMM fault
406F 0518 Error code generation/logging detected
memory DIMM fault
406F 051D Error code generation/logging detected
memory DIMM group fault
406F 051E Error code generation/logging detected
memory DIMM group fault
406F 051F Error code generation/logging detected
memory DIMM group fault
406F 0521 Error code generation/logging detected
memory DIMM fault
406F 0522 Error code generation/logging detected
memory DIMM fault
406F 0523 Error code generation/logging detected
memory DIMM fault
406F 0524 Error code generation/logging detected
memory DIMM fault
406F 0525 Error code generation/logging detected
memory DIMM fault
406F 0526 Error code generation/logging detected
memory DIMM fault
406F 0527 Error code generation/logging detected
memory DIMM fault
406F 0528 Error code generation/logging detected
memory DIMM fault
406F 052D Error code generation/logging detected
memory DIMM group fault
406F 052E Error code generation/logging detected
memory DIMM group pair A fault
406F 052F Error code generation/logging detected
memory DIMM group fault
406F 0531 Error code generation/logging detected
memory DIMM fault
406F 0532 Error code generation/logging detected
memory DIMM fault
406F 0533 Error code generation/logging detected
memory DIMM fault
Action/
Possible Failing FRU
Memory DIMM 11, riser 2
Location: U1.1-P1-M2.11
Memory DIMM 12, riser 2
Location: U1.1-P1-M2.12
Memory DIMM 19, riser 2
Location: U1.1-P1-M2.19
Memory DIMM 20, riser 2
Location: U1.1-P1-M2.20
Memory DIMM 27, riser 2
Location: U1.1-P1-M2.27
Memory DIMM 28, riser 2
Location: U1.1-P1-M2.28
Memory octal B, riser 2
Location: U1.1-P1-M2.3 x8
Memory quad B odd, riser 2
Location: U1.1-P1-M2.3 x4
Memory quad B even, riser 2
Location: U1.1-P1-M2.4 x4
Memory DIMM 5, riser 2
Location: U1.1-P1-M2.5
Memory DIMM 6, riser 2
Location: U1.1-P1-M2.6
Memory DIMM 13, riser 2
Location: U1.1-P1-M2.13
Memory DIMM 14, riser 2
Location: U1.1-P1-M2.14
Memory DIMM 21, riser 2
Location: U1.1-P1-M2.21
Memory DIMM 22, riser 2
Location: U1.1-P1-M2.22
Memory DIMM 29, riser 2
Location: U1.1-P1-M2.29
Memory DIMM 30, riser 2
Location: U1.1-P1-M2.30
Memory octal C, riser 2
Location: U1.1-P1-M2.5 x8
Memory quad C odd, riser 2
Location: U1.1-P1-M2.5 x4
Memory quad C even, riser 2
Location: U1.1-P1-M2.6 x4
Memory DIMM 7, riser 2
Location: U1.1-P1-M2.7
Memory DIMM 8, riser 2
Location: U1.1-P1-M2.8
Memory DIMM 15, riser 2
Location: U1.1-P1-M2.15