Table 7. Service Processor Error Codes (continued)
Error Code Description
450C 51AC Memory system and IPL MOPS detected
595W ac power supply fault
450C 51AD Memory system and IPL MOPS detected
595W dc power supply fault
450C 51AE Memory system and IPL MOPS detected
1100W dc power supply fault
450D 245B Memory system and attention handler
detected 2W 4M processor fault
450D 245C Memory system and attention handler
detected 2W 2M processor fault
450D 245D Memory system and attention handler
detected 4W 4M processor fault
450D 248B Memory system and attention handler
detected primary I/O drawer operator panel
fault
450D 24A5 Memory system and attention handler
detected 2W 500 MHz processor fault
450D 24A6 Memory system and attention handler
detected 4W 500 MHz processor fault
450D 25AB Memory system and attention handler
detected 400 MHz clock fault
450D 25AD Memory system and attention handler
detected 540 MHz clock fault
450D 25B1 Memory system and attention handler
detected 750 MHz clock fault
450D 25B3 Memory system and attention handler
detected 4W 750 MHz processor fault
250D 25B4 Memory system and attention handler
detected 2W 750 MHz processor fault
450D 25DA Memory system and attention handler
detected 500 MHz clock fault
450D 267D Memory system and attention handler
detected an 8W, 750 MHz regulator fault
450D 2687 Memory system and attention handler
detected remote I/O bus adapter fault
450D 271A Memory system and attention handler
detected primary I/O planar fault
Action/
Possible Failing FRU
595W ac power supply
Locations: U0.1-V1
U0.1-V2
595W dc power supply
Locations: U0.1-V1
U0.1-V2
1100W dc power supply
Locations: U1.1-V1
U1.1-V2
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
Operator Panel
Location: U0.1-L1
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
400 MHz clock
Location: U1.1-P1.1.1
540 MHz clock
Location: U1.1-P1.1.1
750 MHz clock
Location: U1.1-P1.1.1
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
500 MHz clock
Location: U1.1-P1.1.1
8W regulator card
Location: U1.1-P1-V1
Remote I/O bus adapter
Location: U0.1-P1.1
Primary I/O planar
Location: U0.1-P1
Chapter 5. Error Code to FRU Index