Table 5. SPCN Error Codes (continued)
Error Code Description
1021 8A00 A different I/O drawer is connected to the
CEC
1021 9012 Invalid address
1021 9013 Invalid address
1021 9014 Invalid address mode
1021 9021 SPCN temporary internal error
1021 9022 Secondary I/O drawer not present
1021 9023 Secondary I/O drawer is present but off
1021 902D Secondary I/O drawer not present
1021 9038 I/O drawer node fault
1021 9039 I/O drawer node fault
1021 9042 EEPROM failure
1021 9043 Download failure
1021 9046 QDS packet sequence error
1021 9047 QDS block sequence error
1021 9080 Undefined status code received
1021 90F0 Drawer not present in configuration table
1021 90F1 Drawer added to configuration table
1021 9102 Permanent address assignment failed
1021 9109 Download failure
1021 9113 Firmware image corrupted
1021 9114 Firmware image corrupted
1021 9116 SPCN communication with operator panel
failure
180
Service Guide
Action/
Possible Failing FRU
Informational only
1. Check SPCN cabling
2. Secondary I/O backplane
Location: U0.2-P1
1. Check SPCN cabling
2. Secondary I/O backplane
Location: U0.2-P1
Update system firmware
Location: U0.1-P1/Y1
Note: Allow up to 30 minutes for this update
to take effect.
Information only
Check cabling
Information only
Information only
Secondary I/O backplane
Location: U0.2-P1
Secondary I/O backplane
Location: U0.2-P1
Secondary I/O backplane
Location: U0.2-P1
1. Check for system firmware update
2. Call second level of support
1. Check for system firmware update
2. Call second level of support
1. Check for system firmware update
2. Call second level of support
Secondary I/O backplane
Location: U0.2-P1
1. Check SPCN cabling
2. Reset system and reboot
3. Secondary I/O backplane
Location: U0.2-P1
Information only
Secondary I/O backplane
Location: U0.2-P1
Secondary I/O backplane
Location: U0.2-P1
Secondary I/O backplane
Location: U0.2-P1
Secondary I/O backplane
Location: U0.2-P1
1. Secondary I/O drawer operator panel
Location: U0.2-L1
2. Secondary I/O backplane
Location: U0.2-P1