Table 6. Firmware Error Codes. (continued)
Error Code Description
20EE 0008 No configurable adapters were found in the
system by the remote IPL menu in the SMS
utilities
20EE 0009 Unable to communicate with the service
processor
20EE 000B The system was not able to find an operating
system boot record on the devices listed in
the boot list. This can be caused by the
wrong devices being in the boot record, a
problem that prevents the system from
communicating with the device that contains
the boot record, or the boot record being
corrupted.
20EE 000C Pointer to the operating system not found in
non-volatile storage.
20FB 0xxx Permanent addressing to map SPCN
addresses to match RIO addresses.
Note: 20FB 0xxx error codes will cause the
system to hang.
Action/
Possible Failing FRU
This warning occurs when the remote IPL
menu in the SMS utilities cannot locate any
LAN adapters that are supported by the
remote IPL function. If a supported device is
installed:
1. Replace the device or adapter.
2. Replace the I/O drawer planar in
thedrawer(s) containing the adapter.
Replace primary I/O drawer backplane
Location: U0.1-P1
Go to "Boot Problems and Concerns" on
page 155.
Values normally found in non-volatile storage
that point to the location of an operating
system were not found. This can happen for
two reasons; either your installed operating
system does not support storing the values or
some event occurred that caused the system
to lose non-volatile storage information
(drainage or replacement of the battery). If
you are running AIX, this information can be
reconstructed by running the bootlist
command specifying the device that the
operating system is installed on. Refer to
your AIX documentation for the exact syntax
and usage of the bootlist command.
To boot the operating system so that the
above mentioned values can be
reconstructed, power the system down and
power it back up again. This should cause
the system to look for the operating system in
the devices contained in the custom boot list
or in the default boot list, depending on the
condition of the system. If this is not
successful, use the System Management
Services menus to modify the boot sequence
(also known as boot list) to include devices
that are known to contain a copy of the
operating system. For example, select a hard
disk known to have a copy of the operating
system as the first and only device in the
boot sequence (boot list) and attempt to boot
again.
Chapter 5. Error Code to FRU Index
197