Table 7. Service Processor Error Codes (continued)
Error Code Description
460E 281D I/O system and scan control routines
detected Model 6M1 CEC backplane fault
460E 285D I/O system and scan control routines
detected SPCN fan controller fault
460E 288A I/O system and scan control routines
detected memory riser card fault
460E 300A I/O system and scan control routines
detected 32 MB DIMM fault
460E 300B I/O system and scan control routines
detected 128 MB DIMM fault
460E 300C I/O system and scan control routines
detected 256 MB DIMM fault
460E 300D I/O system and scan control routines
detected 512 MB (stacked) DIMM fault
460E 300E I/O system and scan control routines
detected 512 MB (unstacked) DIMM fault
460E 301F I/O system and scan control routines
detected 128 MB DIMM fault
460E 303A I/O system and scan control routines
detected 1 GB DIMM fault
460E 515B I/O system and scan control routines
detected 1100W ac power supply fault
460E 51AC I/O system and scan control routines
detected 595W ac power supply fault
460E 51AD I/O system and scan control routines
detected 595W dc power supply fault
460E 51AE I/O system and scan control routines
detected 1100W dc power supply fault
460F 245B I/O system and error code generation/logging
detected 2W 4M processor fault
Action/
Possible Failing FRU
CEC backplane
Location: U1.1-P1
1. SPCN fan controller
Location: U0.1-X2
2. I/O drawer power distribution board
Location: U0.1-X1
1. Go to the service processor Memory
Configuration/Deconfiguration Menu to
verify memory DIMMs state. See
"Memory Configuration/Deconfiguration
Menu" on page 374 for more information.
2. Memory riser card
Locations: U1.1-P1-M1
U1.1-P1-M2
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
1100W ac power supply
Locations: U1.1-V1
U1.1-V2
595W ac power supply
Locations: U0.1-V1
U0.1-V2
595W dc power supply
Locations: U0.1-V1
U0.1-V2
1100W dc power supply
Locations: U1.1-V1
U1.1-V2
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
Chapter 5. Error Code to FRU Index
313

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eserver pseries 660 6m1

Table of Contents