IBM RS/6000 Enterprise Server M80 Service Manual page 237

Hide thumbs Also See for RS/6000 Enterprise Server M80:
Table of Contents

Advertisement

Table 7. Service Processor Error Codes (continued)
Error Code Description
4067 0502 6xx bus processor runtime diagnostics
detected memory DIMM fault
4067 0503 6xx bus processor runtime diagnostics
detected memory DIMM fault
4067 0504 6xx bus processor runtime diagnostics
detected memory DIMM fault
4067 0505 6xx bus processor runtime diagnostics
detected memory DIMM fault
4067 0506 6xx bus processor runtime diagnostics
detected memory DIMM fault
4067 0507 6xx bus processor runtime diagnostics
detected memory DIMM fault
4067 0508 6xx bus processor runtime diagnostics
detected memory DIMM fault
4067 050D 6xx bus processor runtime diagnostics
detected memory DIMM group fault
4067 050E 6xx bus processor runtime diagnostics
detected memory DIMM group pair A fault
4067 050F 6xx bus processor runtime diagnostics
detected memory DIMM group fault
4067 0511 6xx bus processor runtime diagnostics
detected memory DIMM fault
4067 0512 6xx bus processor runtime diagnostics
detected memory DIMM fault
4067 0513 6xx bus processor runtime diagnostics
detected memory DIMM fault
4067 0514 6xx bus processor runtime diagnostics
detected memory DIMM fault
4067 0515 6xx bus processor runtime diagnostics
detected memory DIMM fault
4067 0516 6xx bus processor runtime diagnostics
detected memory DIMM fault
4067 0517 6xx bus processor runtime diagnostics
detected memory DIMM fault
4067 0518 6xx bus processor runtime diagnostics
detected memory DIMM fault
4067 051D 6xx bus processor runtime diagnostics
detected memory DIMM group fault
4067 051E 6xx bus processor runtime diagnostics
detected memory DIMM group fault
4067 051F 6xx bus processor runtime diagnostics
detected memory DIMM group fault
4067 0521 6xx bus processor runtime diagnostics
detected memory DIMM fault
4067 0522 6xx bus processor runtime diagnostics
detected memory DIMM fault
Action/
Possible Failing FRU
Memory DIMM 2, riser 2
Location: U1.1-P1-M2.2
Memory DIMM 9, riser 2
Location: U1.1-P1-M2.9
Memory DIMM 10, riser 2
Location: U1.1-P1-M2.10
Memory DIMM 17, riser 2
Location: U1.1-P1-M2.17
Memory DIMM 18, riser 2
Location: U1.1-P1-M2.18
Memory DIMM 25, riser 2
Location: U1.1-P1-M2.25
Memory DIMM 26, riser 2
Location: U1.1-P1-M2.26
Memory octal A, riser 2
Location: U1.1-P1-M2.1 x8
Memory quad A odd, riser 2
Location: U1.1-P1-M2.1 x4
Memory quad A even, riser 2
Location: U1.1-P1-M2.2 x4
Memory DIMM 3, riser 2
Location: U1.1-P1-M2.3
Memory DIMM 4, riser 2
Location: U1.1-P1-M2.4
Memory DIMM 11, riser 2
Location: U1.1-P1-M2.11
Memory DIMM 12, riser 2
Location: U1.1-P1-M2.12
Memory DIMM 19, riser 2
Location: U1.1-P1-M2.19
Memory DIMM 20, riser 2
Location: U1.1-P1-M2.20
Memory DIMM 27, riser 2
Location: U1.1-P1-M2.27
Memory DIMM 28, riser 2
Location: U1.1-P1-M2.28
Memory octal B, riser 2
Location: U1.1-P1-M2.3 x8
Memory quad B odd, riser 2
Location: U1.1-P1-M2.3 x4
Memory quad B even, riser 2
Location: U1.1-P1-M2.4 x4
Memory DIMM 5, riser 2
Location: U1.1-P1-M2.5
Memory DIMM 6, riser 2
Location: U1.1-P1-M2.6
Chapter 5. Error Code to FRU Index
219

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eserver pseries 660 6m1

Table of Contents