Table 7. Service Processor Error Codes (continued)
Error Code Description
406A 0536 Self test detected memory DIMM fault
406A 0537 Self test detected memory DIMM fault
406A 0538 Self test detected memory DIMM fault
406A 053D Self test detected memory DIMM group fault
406A 053E Self test detected memory DIMM group fault
406A 053F Self test detected memory DIMM group fault
406A 05FF Self test detected memory on riser fault
406A 0600 Self test detected CEC RIO bus adapter
406A 0601 Self test detected clock card fault
406A 3101 Self test detected RIO port 0 fault
406A 3102 Self test detected RIO port 1 fault
406A 3103 Self test detected RIO port 2 fault
406A 3104 Self test detected RIO port 3 fault
406A 3121 Self test detected RIO cable on port 0 fault
406A 3122 Self test detected RIO cable on port 1 fault
406A 3123 Self test detected RIO cable on port 2 fault
406A 3124 Self test detected RIO cable on port 3 fault
406A 3140 Self test detected RIO hub 0 fault
240
Service Guide
Action/
Possible Failing FRU
Memory DIMM 24, riser 2
Location: U1.1-P1-M2.24
Memory DIMM 31, riser 2
Location: U1.1-P1-M2.31
Memory DIMM 32, riser 2
Location: U1.1-P1-M2.32
Memory octal D, riser 2
Location: U1.1-P1-M2.7 x8
Memory quad D odd, riser 2
Location: U1.1-P1-M2.7 x4
Memory quad D even, riser 2
Location: U1.1-P1-M2.8 x4
Memory failure on riser card 2 that cannot be
automatically isolated. go to "MAP 1540:
Minimum Configuration" on page 110 and run
CEC drawer minimum configuration for
further isolation.
CEC RIO bus adapter
Location: U1.1-P1.1
CEC clock card
Location: U1.1-P1.1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 0
Location: U1.1-P1.1/Q1
2. CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 1
Location: U1.1-P1.1/Q2
2. CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 2
Location: U1.1-P1.1/Q3
2. CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 3
Location: U1.1-P1.1/Q4
2. CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1