Table 7. Service Processor Error Codes (continued)
Error Code Description
4067 0601 6xx bus processor runtime diagnostics
detected clock card fault
4067 3101 6xx bus processor runtime diagnostics
detected RIO port 0 fault
4067 3102 6xx bus processor runtime diagnostics
detected RIO port 1 fault
4067 3103 6xx bus processor runtime diagnostics
detected RIO port 2 fault
4067 3104 6xx bus processor runtime diagnostics
detected RIO port 3 fault
4067 3121 6xx bus processor runtime diagnostics
detected RIO cable on port 0 fault
4067 3122 6xx bus processor runtime diagnostics
detected RIO cable on port 1 fault
4067 3123 6xx bus processor runtime diagnostics
detected RIO cable on port 2 fault
4067 3124 6xx bus processor runtime diagnostics
detected RIO cable on port 3 fault
4067 3140 6xx bus processor runtime diagnostics
detected RIO hub 0 fault
4067 3141 6xx bus processor runtime diagnostics
detected RIO hub 1 fault
4067 31FF 6xx bus processor runtime diagnostics
detected RIO port fault
4067 3200 6xx bus processor runtime diagnostics
detected primary I/O drawer fault
4067 3201 6xx bus processor runtime diagnostics
detected primary I/O drawer backplane fault
4067 3280 6xx bus processor runtime diagnostics
detected primary RIO adapter fault
4067 3281 6xx bus processor runtime diagnostics
detected primary RIO port 0 fault
4067 3282 6xx bus processor runtime diagnostics
detected primary RIO port 1 fault
4067 3283 6xx bus processor runtime diagnostics
detected primary RIO ports fault
Action/
Possible Failing FRU
CEC clock card
Location: U1.1-P1.1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 0
Location: U1.1-P1.1/Q1
2. CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 1
Location: U1.1-P1.1/Q2
2. CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 2
Location: U1.1-P1.1/Q3
2. CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 3
Location: U1.1-P1.1/Q4
2. CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
Go to "MAP 1540: Minimum Configuration"
on page 110.
Primary I/O drawer backplane
Location: U0.1-P1
Primary RIO adapter
Location: U0.1-P1.1
1. Check RIO cable
Location: U0.1-P1.1/Q1
2. RIO bus adapter
Location: U0.1-P1.1
1. Check RIO cable
Location: U0.1-P1.1/Q2
2. RIO bus adapter
Location: U0.1-P1.1
RIO bus adapter
Location: U0.1-P1.1
Chapter 5. Error Code to FRU Index