Table 7. Service Processor Error Codes (continued)
Error Code Description
406D 00B1 Attention handler detected bus controller
failure
406D 00B3 Attention handler detected clock fault
406D 00B7 Attention handler detected insufficient
hardware resources to continue IPL
406D 0200 Attention handler detected memory riser card
fault
406D 0201 Attention handler detected memory DIMM
fault
406D 0202 Attention handler detected memory DIMM
fault
406D 0203 Attention handler detected memory DIMM
fault
406D 0204 Attention handler detected memory DIMM
fault
406D 0205 Attention handler detected memory DIMM
fault
406D 0206 Attention handler detected memory DIMM
fault
406D 0207 Attention handler detected memory DIMM
fault
406D 0208 Attention handler detected memory DIMM
fault
406D 020D Attention handler detected memory DIMM
group fault
406D 020E Attention handler detected memory DIMM
group fault
406D 020F Attention handler detected memory DIMM
group fault
406D 0211 Attention handler detected memory DIMM
fault
406D 0212 Attention handler detected memory DIMM
fault
406D 0213 Attention handler detected memory DIMM
fault
406D 0214 Attention handler detected memory DIMM
fault
406D 0215 Attention handler detected memory DIMM
fault
Action/
Possible Failing FRU
RIO bus adapter
Location: U0.1-P1.1
1. Clock card
Location: U1.1-P1.1.1
2. CEC RIO bus adapter
Location: U1.1-P1.1
This error code appears after the initial
testing by the service processor firmware on
the CEC was completed correctly, but a
problem occurred when the firmware tried to
communicate outside the CEC. Suspect a
problem with the RIO interface, either cables
or adapters.
Memory riser card 1
Location: U1.1-P1-M1
Memory DIMM 1, riser 1
Location: U1.1-P1-M1.1
Memory DIMM 2, riser 1
Location: U1.1-P1-M1.2
Memory DIMM 9, riser 1
Location: U1.1-P1-M1.9
Memory DIMM 10, riser 1
Location: U1.1-P1-M1.10
Memory DIMM 17, riser 1
Location: U1.1-P1-M1.17
Memory DIMM 18, riser 1
Location: U1.1-P1-M1.18
Memory DIMM 25, riser 1
Location: U1.1-P1-M1.25
Memory DIMM 26, riser 1
Location: U1.1-P1-M1.26
Memory octal A, riser 1
Location: U1.1-P1-M1.1 x8
Memory quad A odd, riser 1
Locations: U1.1-P1-M1.1 x4
Memory quad A even, riser 1
Locations: U1.1-P1-M1.2 x4
Memory DIMM 3, riser 1
Location: U1.1-P1-M1.3
Memory DIMM 4, riser 1
Location: U1.1-P1-M1.4
Memory DIMM 11, riser 1
Location: U1.1-P1-M1.11
Memory DIMM 12, riser 1
Location: U1.1-P1-M1.12
Memory DIMM 19, riser 1
Location: U1.1-P1-M1.19
Chapter 5. Error Code to FRU Index