IBM RS/6000 Enterprise Server M80 Service Manual page 290

Hide thumbs Also See for RS/6000 Enterprise Server M80:
Table of Contents

Advertisement

Table 7. Service Processor Error Codes (continued)
Error Code Description
406F 0534 Error code generation/logging detected
memory DIMM fault
406F 0535 Error code generation/logging detected
memory DIMM fault
406F 0536 Error code generation/logging detected
memory DIMM fault
406F 0537 Error code generation/logging detected
memory DIMM fault
406F 0538 Error code generation/logging detected
memory DIMM fault
406F 053D Error code generation/logging detected
memory DIMM group fault
406F 053E Error code generation/logging detected
memory DIMM group fault
406F 053F Error code generation/logging detected
memory DIMM group fault
406F 05FF Error code generation/logging detected
memory on riser fault
406F 0600 Error code generation/logging detected CEC
RIO bus adapter
406F 0601 Error code generation/logging detected clock
card fault
406F 3101 Error code generation/logging detected RIO
port 0 fault
406F 3102 Error code generation/logging detected RIO
port 1 fault
406F 3103 Error code generation/logging detected RIO
port 2 fault
406F 3104 Error code generation/logging detected RIO
port 3 fault
406F 3121 Error code generation/logging detected RIO
cable on port 0 fault
406F 3122 Error code generation/logging detected RIO
cable on port 1 fault
406F 3123 Error code generation/logging detected RIO
cable on port 2 fault
272
Service Guide
Action/
Possible Failing FRU
Memory DIMM 16, riser 2
Location: U1.1-P1-M2.16
Memory DIMM 23, riser 2
Location: U1.1-P1-M2.23
Memory DIMM 24, riser 2
Location: U1.1-P1-M2.24
Memory DIMM 31, riser 2
Location: U1.1-P1-M2.31
Memory DIMM 32, riser 2
Location: U1.1-P1-M2.32
Memory octal D, riser 2
Location: U1.1-P1-M2.7 x8
Memory quad D odd, riser 2
Location: U1.1-P1-M2.7 x4
Memory quad D even, riser 2
Location: U1.1-P1-M2.8 x4
Memory failure on riser card 2 that cannot be
automatically isolated. go to "MAP 1540:
Minimum Configuration" on page 110 and run
CEC drawer minimum configuration for
further isolation.
CEC RIO bus adapter
Location: U1.1-P1.1
CEC clock card
Location: U1.1-P1.1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 0
Location: U1.1-P1.1/Q1
2. CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 1
Location: U1.1-P1.1/Q2
2. CEC RIO bus adapter
Location: U1.1-P1.1
1. RIO cable on port 2
Location: U1.1-P1.1/Q3
2. CEC RIO bus adapter
Location: U1.1-P1.1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eserver pseries 660 6m1

Table of Contents