Table 7. Service Processor Error Codes (continued)
Error Code Description
4066 0217 Scan interface basic assurance tests
detected memory DIMM fault
4066 0218 Scan interface basic assurance tests
detected memory DIMM fault
4066 021D Scan interface basic assurance tests
detected memory DIMM group fault
4066 021E Scan interface basic assurance tests
detected memory DIMM group pair A fault
4066 021F Scan interface basic assurance tests
detected memory DIMM group fault
4066 0221 Scan interface basic assurance tests
detected memory DIMM fault
4066 0222 Scan interface basic assurance tests
detected memory DIMM fault
4066 0223 Scan interface basic assurance tests
detected memory DIMM fault
4066 0224 Scan interface basic assurance tests
detected memory DIMM fault
4066 0225 Scan interface basic assurance tests
detected memory DIMM fault
4066 0226 Scan interface basic assurance tests
detected memory DIMM fault
4066 0227 Scan interface basic assurance tests
detected memory DIMM fault
4066 0228 Scan interface basic assurance tests
detected memory DIMM fault
4066 022D Scan interface basic assurance tests
detected memory DIMM group fault
4066 022E Scan interface basic assurance tests
detected memory DIMM group pair A fault
4066 022F Scan interface basic assurance tests
detected memory DIMM group fault
4066 0231 Scan interface basic assurance tests
detected memory DIMM fault
4066 0232 Scan interface basic assurance tests
detected memory DIMM fault
4066 0233 Scan interface basic assurance tests
detected memory DIMM fault
4066 0234 Scan interface basic assurance tests
detected memory DIMM fault
4066 0235 Scan interface basic assurance tests
detected memory DIMM fault
4066 0236 Scan interface basic assurance tests
detected memory DIMM fault
4066 0237 Scan interface basic assurance tests
detected memory DIMM fault
Action/
Possible Failing FRU
Memory DIMM 27, riser 1
Location: U1.1-P1-M1.27
Memory DIMM 28, riser 1
Location: U1.1-P1-M1.28
Memory octal B, riser 1
Location: U1.1-P1-M1.3 x8
Memory quad B odd, riser 1
Location: U1.1-P1-M1.3 x4
Memory quad B even, riser 1
Location: U1.1-P1-M1.4 x4
Memory DIMM 5, riser 1
Location: U1.1-P1-M1.5
Memory DIMM 6, riser 1
Location: U1.1-P1-M1.6
Memory DIMM 13, riser 1
Location: U1.1-P1-M1.13
Memory DIMM 14, riser 1
Location: U1.1-P1-M1.14
Memory DIMM 21, riser 1
Location: U1.1-P1-M1.21
Memory DIMM 22, riser 1
Location: U1.1-P1-M1.22
Memory DIMM 29, riser 1
Location: U1.1-P1-M1.29
Memory DIMM 30, riser 1
Location: U1.1-P1-M1.30
Memory octal C, riser 1
Locations: U1.1-P1-M1.5 x8
Memory quad C odd, riser 1
Locations: U1.1-P1-M1.5 x4
Memory quad C even, riser 1
Locations: U1.1-P1-M1.6 x4
Memory DIMM 7, riser 1
Location: U1.1-P1-M1.7
Memory DIMM 8, riser 1
Location: U1.1-P1-M1.8
Memory DIMM 15, riser 1
Location: U1.1-P1-M1.15
Memory DIMM 16, riser 1
Location: U1.1-P1-M1.16
Memory DIMM 23, riser 1
Location: U1.1-P1-M1.23
Memory DIMM 24, riser 1
Location: U1.1-P1-M1.24
Memory DIMM 31, riser 1
Location: U1.1-P1-M1.31
Chapter 5. Error Code to FRU Index