Table 7. Service Processor Error Codes (continued)
Error Code Description
4068 3124 Other bus processor runtime diagnostics
detected RIO cable on port 3 fault
4068 3140 Other bus processor runtime diagnostics
detected RIO hub 0 fault
4068 3141 Other bus processor runtime diagnostics
detected RIO hub 1 fault
4068 31FF Other bus processor runtime diagnostics
detected RIO port fault
4068 3200 Other bus processor runtime diagnostics
detected primary I/O drawer fault
4068 3201 Other bus processor runtime diagnostics
detected primary I/O drawer backplane fault
4068 3280 Other bus processor runtime diagnostics
detected primary RIO adapter fault
4068 3281 Other bus processor runtime diagnostics
detected primary RIO port 0 fault
4068 3282 Other bus processor runtime diagnostics
detected primary RIO port 1 fault
4068 3283 Other bus processor runtime diagnostics
detected primary RIO ports fault
4068 3284 Other bus processor runtime diagnostics
detected PCI controller PHB0
4068 3285 Other bus processor runtime diagnostics
detected PCI controller PHB1
4068 3286 Other bus processor runtime diagnostics
detected PCI controller PHB2
4069 0001 Memory test detected CEC backplane failure
4069 0003 Memory test detected processor fault
4069 0009 Memory test detected memory fault
4069 00A0 Memory test detected CSP service processor
firmware fault
4069 00A1 Memory test detected AIX or system firmware
fault
228
Service Guide
Action/
Possible Failing FRU
1. RIO cable on port 3
Location: U1.1-P1.1/Q4
2. CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
CEC RIO bus adapter
Location: U1.1-P1.1
Go to "MAP 1540: Minimum Configuration"
on page 110.
Primary I/O drawer backplane
Location: U0.1-P1
Primary RIO adapter
Location: U0.1-P1.1
1. Check RIO cable
Location: U0.1-P1.1/Q1
2. RIO bus adapter
Location: U0.1-P1.1
1. Check RIO cable
Location: U0.1-P1.1/Q2
2. RIO bus adapter
Location: U0.1-P1.1
RIO bus adapter
Location: U0.1-P1.1
1. RIO bus adapter
Location: U0.1-P1.1
2. Primary I/O drawer backplane
Location: U0.1-P1
1. RIO bus adapter
Location: U0.1-P1.1
2. Primary I/O drawer backplane
Location: U0.1-P1
1. RIO bus adapter
Location: U0.1-P1.1
2. Primary I/O drawer backplane
Location: U0.1-P1
CEC backplane
Location: U1.1-P1
All processors
Location: U1.1-P1-C1
All memory
Location: U1.1-P1-M1 x2
Update system firmware
Location: U0.1-P1/Y1
1. Check for AIX updates
2. Check for system firmware updates
Location: U0.1-P1/Y1

Advertisement