IBM RS/6000 Enterprise Server M80 Service Manual page 346

Hide thumbs Also See for RS/6000 Enterprise Server M80:
Table of Contents

Advertisement

Table 7. Service Processor Error Codes (continued)
Error Code Description
4B2B 288A Processor system and wire test detected
memory riser card fault
4B2B 300A Processor system and wire test detected 32
MB DIMM fault
4B2B 300B Processor system and wire test detected 128
MB DIMM fault
4B2B 300C Processor system and wire test detected 256
MB DIMM fault
4B2B 300D Processor system and wire test detected 512
MB (stacked) DIMM fault
4B2B 300E Processor system and wire test detected 512
MB (unstacked) DIMM fault
4B2B 301F Processor system and wire test detected 128
MB DIMM fault
4B2B 303A Processor system and wire test detected 1
GB DIMM fault
4B2B 515B Processor system and wire test detected
1100W ac power supply fault
4B2B 51AC Processor system and wire test detected
595W ac power supply fault
4B2B 51AD Processor system and wire test detected
595W dc power supply fault
4B2B 51AE Processor system and wire test detected
1100W dc power supply fault
4B2C 245B Processor system and IPL MOPS detected
2W 4M processor fault
4B2C 245D Processor system and IPL MOPS detected
4W 4M processor fault
4B2C 248B Processor system and IPL MOPS detected
primary I/O drawer operator panel fault
4B2C 24A5 Processor system and IPL MOPS detected
2W 500 MHz processor fault
328
Service Guide
Action/
Possible Failing FRU
1. Go to the service processor Memory
Configuration/Deconfiguration Menu to
verify memory DIMMs state. See
"Memory Configuration/Deconfiguration
Menu" on page 374 for more information.
2. Memory riser card
Locations: U1.1-P1-M1
U1.1-P1-M2
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
1100W ac power supply
Locations: U1.1-V1
U1.1-V2
595W ac power supply
Locations: U0.1-V1
U0.1-V2
595W dc power supply
Locations: U0.1-V1
U0.1-V2
1100W dc power supply
Locations: U1.1-V1
U1.1-V2
Go to "MAP 1540: Minimum Configuration"
on page 110.
Go to "MAP 1540: Minimum Configuration"
on page 110.
Operator Panel
Location: U0.1-L1
Go to "MAP 1540: Minimum Configuration"
on page 110.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eserver pseries 660 6m1

Table of Contents