press, the following actions by the user will trigger a forced eject:
Two more momentary presses within 5 minutes of the first press, or
Three momentary presses in any subsequent 5 minute period, or
One long press where the button is held down for at least 5 seconds.
Note also that, for the purposes of triggering a forced eject, a SCSI unload command may be taken to be
functionally equivalent to pressing the eject button for the first time. When the drive is self-configuring after
a power cycle or a SCSI hard reset, the eject button is ignored for a period of about five seconds. This
happens because the drive is running kernel diagnostics and the main firmware has not yet started to run.
During this time eject button presses will not register and will not contribute towards the forced eject trigger
criteria.

Forced Eject Action

Once a forced eject has been triggered, the drive will wait for a period of approximately 35 seconds from
the time of the first press (the one that attempted to start the normal eject). Once this time-out, or period of
grace, has passed the drive will carry out a forced eject. This will cause the tape to be immediately
unthreaded and ejected regardless of any operation that the drive may be carrying out. Once the tape has
been ejected a firmware reset will be carried out as if the drive had been power cycled.

Consequences of a Forced Eject

The drive can be performing any action at the time a forced eject is executed. There is a possibility that
during a write, data may be lost and an invalid format tape could be created (as EOD may not be written
correctly). It is for this reason that the drive allows itself the 35 second grace period in which to attempt a
normal eject. If the normal eject succeeds within the 35 second period, then any pending forced eject will
be cancelled.
Beware also that as the firmware is fully reset at the end of the forced eject sequence, the drive will re-instate
its default setup and will lose any special features that may have been enabled by a prior mode select
command. The drive's internal trace logs will also be cleared. A forced eject will override any Prevent
Medium Removal status that may have been previously ordered by the host system. The forced eject feature
is factory configured and cannot be defeated.

Manual Cartridge Removal

If a tape cartridge becomes jammed in the tape drive, it can be extracted by performing the fol-
lowing steps:
Read these instructions fully before starting the procedure.
1. Remove the tape drive from the SPU cabinet. Refer to the Peripheral Bay removal procedure in
Chapter 7.
2. Remove the tape drive mounting brackets.
3. Remove the tape drive top cover.
4. See Figure 8-53. Insert a size 00 cross head screwdriver through the emergency eject access hole.
(Some early revisions of the mechanism have single slots in the end of the worm gear, use a flat
blade screwdriver in this case.)
5. Watch the tip of the screwdriver from the left hand side of the tape drive and angle the screwdriver
8-90
SCSI and I/O
Note