QuickSpecs
Overview
HP Integrity Superdome Servers 16-socket, 32-socket,
HP Integrity Superdome Servers 16-socket, 32-socket,
HP Integrity Superdome Servers 16-socket, 32-socket,
HP Integrity Superdome Servers 16-socket, 32-socket,
DA - 11717
Worldwide — Version 20 — May 3, 2005
and 64-socket
and 64-socket
and 64-socket
and 64-socket
Page 1

Advertisement

loading

Summary of Contents for HP Integrity Superdome 16-socket

  • Page 1 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Overview DA - 11717 Worldwide — Version 20 — May 3, 2005...
  • Page 2 It is the dawn of a new era in high end computing with the emergence of commodity based hardware. Superdome supports a multi OS environment. Currently, HP UX, Windows Server 2003, Red Hat RHEL AS 3, and SUSE SLES 9 are shipping with Integrity Superdome Customers can order any combination of HP UX 11i v2, Windows Server 2003, Datacenter Edition, or RHEL AS 3, running in separate hard partitions.
  • Page 3 Proactive 24 included in your solution, you optimize the effectiveness of your IT environment with access to an HP-certified team of experts that can help you identify potential areas of improvement in key IT processes and implement necessary changes to increase availability.
  • Page 4: Standard Features

    HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Standard Features Minimum/Maximum Configurations for Superdome with Intel Itanium 2 Processors (1.5-GHz and 1.6-GHz) Minimum/Maximum Configurations for Superdome with Intel Itanium 2 Processors (1.5-GHz and 1.6-GHz)
  • Page 5 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Standard Features System Size System Size System Size...
  • Page 6 They will also house most (usually all) of the system's PCI-X cards. Systems may include both left and right cabinet assemblies containing, a left or right backplane respectively. One or more HP Rack System/E cabinets. These 19-inch rack cabinets are used to hold the system peripheral devices such as disk drives.
  • Page 7 Each backplane cabinet can support up to eight cells. A backplane supporting four cells results in a 16-socket Superdome (16-way PA 8600/PA 8700 or 32 way PA 8800 ). Similarly, a backplane supporting eight cells would result in a 32-socket Superdome (32-way PA 8600/PA 8700 or 64-way PA 8800).
  • Page 8 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Configuration HP-UX Core I/O HP-UX Core I/O...
  • Page 9 Rosebowl I, pre-merger Compaq, Rittal, or other third-party racks. The I/O expansion cabinet is based on a modified HP Rack System E and all expansion components mount in the rack. Each component is designed to install independently in the rack. The Rack System E cabinet has been modified to allow I/O interface cables to route between the ICE and cell boards in the Superdome cabinet.
  • Page 10 Superdome supports HP UX 11i version 2, Windows Server 2003, Datacenter Edition, SUSE SLES 9 and Red Hat RHEL AS 3 operating systems. The diagram below shows a multi OS environment within Superdome.
  • Page 11 HP Product Structure 0D1 - factory integration B01 - on site installation at customer's location (must contact HP Services for a quote to install on- site!) ABA - English localization only (other languages, Ger, Fre, Ita available only as a special with...
  • Page 12 (SPOFs) and no ability to propagate failures between systems. However, HP supports the configuration of HA cluster software in a single system to allow DA - 11717 Worldwide —...
  • Page 13 Since no single system solution in the industry provides protection against a SPOF, users that still need this kind of safety and HP's highest availability should use HA cluster software in a multiple system HA configuration. Multiple HA software clusters can be configured within a single Superdome system (i.e., two 4-node clusters configured...
  • Page 14 HBA, AB466A or AB467A. Additionally, the NCU (NIC Configuration Utility), which is provided from HP on the SmartSetup CD that ships with Windows partitions, can also be used in conjunction with MSCS clusters with the HP supported Windows NIC cards.
  • Page 15 NOTE 1: NOTE 1: Windows Server 2003 Datacenter Edition must be installed by HP. If factory installation is selected, then a qualified Windows storage device must be ordered and an A9890A, AB466A or AB467A card must be ordered. There must be at least one boot drive for each partition.
  • Page 16: Management Features

    In general, the service processor (MP) on Superdome servers is similar to the service processor on other HP servers, while providing enhanced features necessary for managing a multiple-nPartition server. For example, the service processor manages the complex profile, which defines nPartition configurations as well as complex-wide settings for the server.
  • Page 17 It also enables remote support by factory experts who consult with and back up the HP Customer Engineer. The SMS complements the proactive role of HP's Instant Support Enterprise Edition (ISEE) that is offered to Mission Critical customers by focusing on reactive diagnosis for both mission critical and non mission critical Superdome customers.
  • Page 18 This may be a concern for some customers, and may dictate special LAN configurations. If an HP-UX workstation is used as a console device, an hpterm window running telnet is the recommended way to connect to the MP. If a PC is used as a console device, Reflection1 configured for hpterm emulation and telnet connection is the recommended way to connect to the The MP currently supports a maximum of 16 telnet-connected users at any one time.
  • Page 19 Console over the LAN. This means that a PC or HP workstation can become the system console if properly connected on the customer LAN. This feature becomes especially important because of the remote power management capability.
  • Page 20 A legacy UNIX SMS could be an A400, A500, rp2430 or rp2470 bundle, depending on when it was ordered In order for a legacy SMS to be upgraded to support Integrity or PA8800, it must be running HP-UX 11.0 or later, as sx1000 scan tools are not supported on HP-UX 10.20.
  • Page 21 This is for cases in which the Customer does not want the SMS to be on a public network, and HP Field Services needs to access the SMS (they would then access the SMS via the phone line and PCAnywhere.)
  • Page 22 All SMS software is preloaded in the factory and delivered to the customer as a complete solution. The UNIX rx2600 SMS supports only HP UX 11i at this time. Current versions of the SMS software have not been qualified for 64 bit Windows.
  • Page 23 The Windows ProLiant SMS cannot be used to manage PA-8700 Superdomes The UNIX rx2600 SMS can be used to manage all current models of Superdome A legacy UNIX SMS can manage Integrity Superdomes as long as it undergoes a software upgrade and is running HP-UX 11.0...
  • Page 24 Runs locally on a partition, or remotely. The Partition Manager application can be run remotely on any system running HP-UX 11i Version 2 and eventually select Windows releases and remotely manage a complex either by 1) communicating with a booted OS on an nPartition in the target complex via WBEM, or 2) communicating with the service processor in the target complex via IPMI over LAN.
  • Page 25 HP management agents that assist in the server deployment process by preparing the server for installation of standard Windows operating system and in the on going management of the server. Please note that this is available for HP service personnel but not provided to end customers.
  • Page 26 NOTE: At first release, Partition Manager will require an HP-UX 11i Version 2 partition or separate device (i.e. Itanium2 based workstation or server running HP-UX 11i Version 2) in order to configure Red Hat or SUSE partitions. Refer to HP UX section above for key features of Partition Manager. HP's Management Processor...
  • Page 27 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Configuration Ability to scan a cell board while the system is running. (only available for partitionable...
  • Page 28 6:00 o'clock. a. In-line connector is available from HP by purchasing A6440A, Option 401. b. Panel mount receptacles must be purchased by the customer from a local Mennekes supplier. c. In-line connector is available from HP by purchasing A6440A, Option 501.
  • Page 29 HP has teamed with Liebert to develop an innovative data room cooling solution called DataCool. DataCool is a patented overhead climate system utilizing fluid based cooling coils and localized blowers capable of cooling heat loads of several hundred watts per square foot.
  • Page 30 Uninterruptible Power Supplies (UPS) Uninterruptible Power Supplies (UPS) HP will be reselling-high end (10 kW and above) three-phase UPS systems from our partners. We will test and qualify a three-phase UPS for Superdome. All third-party UPS resold by HP are tested and qualified by HP to ensure interoperability with our...
  • Page 31 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Configuration Product Product Product Product Quantity/ Quantity/...
  • Page 32 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Configuration Power Protection Power Protection Power Protection...
  • Page 33 The APC SL20KFB2 units are designed to kick in before the AC power drops below the operating range of the HP Superdome Enterprise Server. Therefore, these UPS units may run on battery frequently if the AC power source consistently dips below the threshold voltage.
  • Page 34 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Configuration Category Category Rule Index Rule Index...
  • Page 35 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Configuration If a partition contains 4 or fewer cells, all the cells should be linked to the same crossbar (quad) in order to eliminate bottlenecks and the sharing of crossbar bandwidth with other partitions.
  • Page 36 This is needed to allow HP-UX to boot. The customer does not need to order the terminators for these factory integrated SCSI cards, since the customer will probably discard them. The terminators are provided in the factory by use of constraint net logic.
  • Page 37 Superdome/PA-8800 128-socket system and two nodes in another dual cabinet Superdome/64-socket system or Superdome/PA-8800 128-socket system). The Quorum Service can support up to 50 clusters or 100 nodes (can be arbitrator to both HP-UX and Linux clusters). Two-cabinet configurations must evenly divide nodes between the cabinets (i.e. 3 and 1 is not a legal 4-node configuration).
  • Page 38 In the unlikely event that a CPU fails, the HP system will replace the failed CPU on the cell board at no additional charge. The Instant Capacity CPU brings the system back to full performance and capacity levels, reducing downtime and ensuring no degradation in performance.
  • Page 39 In the unlikely event that a cell board fails, the HP system will replace the cell board at no additional charge. The ICAP cell board brings the system back to full performance and capacity levels, reducing downtime and ensuring no degradation in performance.
  • Page 40 Additionally, with HP retaining ownership of the server, technology obsolescence and underutilized processing assets are no longer a customer concern. This is the cornerstone of HP's pay-as-you-go Utility Pricing. Customers will be able to benefit from their servers as a "compute utility". Customers will choose when to apply additional CPU capacity and will only be charged when the additional processing power is utilized.
  • Page 41 Windows Windows Pay per Use is now available for HP Integrity Superdome systems running Microsoft Windows Server 2003 Datacenter edition (64 bit) under the Percent CPU model. However, at the present time there is no Active CPU offering and there is no iICAP offering for Windows on Integrity. The Windows PPU LTU product number is T2765AA and option -001 must be ordered for each CPU.
  • Page 42 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Upgrades For information on Superdome System Upgrades, please refer to the Superdome Server Upgrades QuickSpec.
  • Page 43 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Memory Total Total Total Total No. of No.
  • Page 44 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Memory NOTES NOTES: NOTES NOTES 1. Configurations with 8, 16, or 32 DIMMs will result in the best performance 2.
  • Page 45: Technical Specifications

    HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Technical Specifications Superdome Superdome Superdome Superdome SPU Description...
  • Page 46 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Technical Specifications HP-UX revision HP- UX 11i version 2 Windows revision Windows Server 2003, Datacenter Edition for Itanium 2.
  • Page 47 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Technical Specifications Typical 3 Phase 5Wire 10A / Phase...
  • Page 48 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Technical Specifications Regulatory Compliance Regulatory Compliance Regulatory Compliance...
  • Page 49 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Technical Specifications General Features General Features 0% to 95% non-condensing, 200% overload capability, Audible Alarms,...
  • Page 50 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Technical Specifications Optional Management See APC website http://www.apcc.com...
  • Page 51 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Technical Specifications PCI X 1 channel 2 Gb /sFibre...
  • Page 52 NOTE: NOTE: NOTE: MSA30 SB/DB are supported as boot disks for Superdome running HP UX 11i with the following cards: A7173A, A6828A, A6829A and A5838A. Please refer to the table below as guidance for configuring your Windows Server 2003 partition...
  • Page 53 0,1,5,1+0 and ADG are supported as well as disk sparing. Note that booting from external storage arrays is now supported (HP XP and EVA storage). In these cases, it is recommended by HP that the FC-HBAs are configured in a redundant pair using HP Secure Path software for high availability.
  • Page 54 HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, HP Integrity Superdome Servers 16-socket, 32-socket, QuickSpecs and 64-socket and 64-socket and 64-socket and 64-socket Technical Specifications EMC CLARiiON CX 400/CX600 EMC CLARiiON CX300/CX500/CX700...
  • Page 55 Each A5838A PCI 2-port 100Base-T 2-port Ultra2 SCSI card that supports a Surestore Disk System SC10 (A5272AZ) will need quantity two (2) of product number C2370A (terminator); otherwise it must have a terminated cable in place prior to HP UX boot.