The Default jumper settings are:
J2: Remote = open
Auto Spin-up = shorted
J3: Pin sets 1 through 4 = Address dependent
Pin sets 5 and 6 = open
Preventative Maintenance
There is no preventative maintenance required for this product.
Troubleshooting
Front Panel LED Indicator
The light emitting diode (LED) on the front of the disk drive is an activity light that indicates the operational
status of the drive from power-on, through the self -test diagnostics, and into normal operation.
ON
FLASHING
INTERMITTENT
Exchange part number
The exchange part number is: C2490-69375
Diagnostics
•
SCSIDISK2
•
SYSMAP
•
IOMAP
At Power-On, the LED turns on until the power-on sequence is completed and then turns
off.
If Auto-Spin Up is enabled, the Power-On sequence includes execution of the Spin Up
sequence, calibrating the head positioning electronics, and testing of the read/write sys-
tems. (DEFAULT setting)
If Auto-Spin Up is not enabled, the Power-On sequence includes the execution of the
Spin Up sequence only.
A flashing LED (approximately 1 Hz) indicates that the controller has failed all or a por-
tion of the internal diagnostic tests.
After power-on diagnostics have completed, the LED functions as an activity light and
will go on any time the disk drive is executing a command, reading, or writing. If the
LED is off, the drive is idle.
SCSI and I/O
8-35