HP-UX Procedure:
1. Reset the system.
2. Stop the autoboot process if it is enabled.
3. From PDC service menu, enter the
timestamps, chassis codes, responder/requestor addresses, I/O module error log, and memory error
log.
4. Refer to Table 3-12 for description and action for each HPMC chassis code. Table 3-13 identifies the
slot numbers on the Processor/Memory bus.
MPE/iX Procedure:
1. Perform a TOC.
2. From the PDC service menu, enter the
timestamps, chassis codes, responder/requestor addresses, I/O module error log, and memory error
log.
3. Perform a memory dump (refer to Performing a Memory Dump section).
4. Refer to Table 3-12 for description and action for each HPMC chassis code.
For Major Category 5 (Bus Transactions) Chassis Codes, the Master ID (MID) will identify the CPU or IOA
as follows:
Description
CPU 0
CPU 1
CPU 2
CPU 3
CPU 4
CPU 5
IOA 0 (system board)
IOA 1 (system board)
IOA 0 (HSC expansion I/O)
IOA 1 (HSC expansion I/O)
MMC
command. Record or print the PIM report, specifically
PIM
command. Record or print the PIM report, specifically
PIM
K2x0/K4x0
SPA
FFFA0000
0
FFFA2000
1
FFFA4000
2
FFFA6000
3
FFFAC000
—
FFFAE000
—
FFF88000
4
FFF8A000
5
FFF8C000
—
FFF8E000
—
FFFB1000
7
K370/K380
K570/K580
MID
0
0
1
1
2
2
3
3
6
6
7
7
4
4
5
5
—
6
—
7
—
—
Troubleshooting
3-17