HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, QuickSpecs and 64-way and 64-way and 64-way and 64-way Overview DA - 11717 Worldwide — Version 1 — June 30, 2003...
Page 2
At A Glance The latest release of Superdome, HP Integrity Superdome supports the new and improved sx1000 chip set. HP Integrity Superdome supports Itanium 2 1.5- GHz processors in mid 2003, and the next generation PA RISC processor, PA 8800 and the mx2 processor module based on two Itanium 2 processors in early 2004.
Page 3
With HP Proactive 24 included in your solution, you optimize the effectiveness of your IT environment with access to an HP certified team of experts that can help you identify potential areas of improvement in key IT processes and implement necessary changes to increase availability.
HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, QuickSpecs and 64-way and 64-way and 64-way and 64-way Standard Features System System System System HP UX 11i version 2...
Page 5
Each backplane cabinet can support up to eight cells or 32 processors (in a Superdome 32- way in a single cabinet). A backplane supporting four cells or 16 processors would result in a Superdome 16-way. Two backplanes can be linked together with flex cables to produce a cabinet that can support up to 16 cells or 64 processors (Superdome 64-way in dual cabinets).
Page 6
I/O chassis. A 4 cell Superdome (16-way) supports up to four I/O chassis for a maximum of 48 PCI X slots. An 8 cell Superdome supports up to eight I/O chassis for a maximum of 96 PCI X slots. Four of these I/O chassis will reside in an I/O expansion cabinet.
Page 7
The I/O expansion cabinet is based on a modified HP Rack System E and all expansion components mount in the rack. Each component is designed to install independently in the rack. The Rack System E cabinet has been modified to allow I/O interface cables to route between the ICE and cell boards in the Superdome cabinet.
Page 8
Partitions Partitions Superdome can be configured with hardware partitions, (npars). Given that HP-UX 11i version 2 does not support virtual partitions (vpars), Superdome systems running HP-UX 11i version 2 do not support vpars. A hardware partition (npar) consists of one or more cells that communicate coherently over a high bandwidth, low latency crossbar fabric.
Page 9
CPU: The features below nearly eliminate the down time associated with CPU cache errors (which are the majority of CPU errors). If a CPU is exhibiting excessive cache errors, HP-UX 11i version 2 will ONLINE activate to take its place. Furthermore, the CPU cache will automatically be repaired on reboot, eliminating the need for a service call.
Page 10
HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, QuickSpecs and 64-way and 64-way and 64-way and 64-way Configuration HP-UX: Serviceguard and Serviceguard Extension for RAC...
Page 11
LAN configurations. If an HP-UX workstation is used as a console device, an hpterm window running telnet is the recommended way to connect to the MP. If a PC is used as a console device, Reflection1 configured for hpterm emulation and telnet connection is the recommended way to connect to the MP.
Page 12
Superdome customers. The user of the SMS is the HP Customer Engineer and HP Factory Support Engineer. The Superdome customer benefits from their use of the SMS by receiving faster return to normal operation of their Superdome server, and improved accuracy of fault diagnosis, resulting in fewer callbacks.
Page 13
Software Distributor (SD) is the HP-UX administration tool set used to deliver and maintain HP-UX operating Software Distributor (SD) Software Distributor (SD) systems and layered software applications. Delivered as part of HP-UX, SD can help you manage your HP-UX operating system, patches, and application software on HP Itanium2 based servers. System Administration Manager (SAM)
Page 14
OpenView Data Protector (Omniback II)-backs up and recovers data (fee based) In addition, the Network Node Manager (NNM) management station will run on HP-UX Itanium 2 based servers. NNM automatically discovers, draws (maps), and monitors networks and the systems connected to them.
Page 15
Windows operating system and in the on going management of the server. Please note that this is available for HP service personnel but not provided to end customers.
Page 16
64-way and 64-way and 64-way Configuration Itanium2 based workstation or server running HP-UX 11i Version 2) in order to configure Linux partitions. Refer to HP-UX section above for key features of Partition Manager. HP's Management Processor HP's Management Processor HP's Management Processor HP's Management Processor enables remote server management over the Web regardless of the system state.
Page 17
2, grounded at 6:00 o'clock. a. In line connector is available from HP by purchasing A6440A, Option 401. b. Panel mount receptacles must be purchased by the customer from a local Mennekes supplier. c. In line connector is available from HP by purchasing A6440A, Option 501.
Page 18
Uninterruptible Power Supplies (UPS) Uninterruptible Power Supplies (UPS) HP will be reselling high-end (10-kW and above) three-phase UPS systems from our partners. We will test and qualify a three-phase UPS for Superdome. The UPS is planned to be available Q1 FY01.
Page 19
HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, QuickSpecs and 64-way and 64-way and 64-way and 64-way Configuration For more information on the product and to manage the reference sales process. Please go to http://hpcp.grenoble.hp.com/...
Page 20
92 VAC in a 110 VAC area. Heavy-load electrical equipment or power rationing are some of the reasons these situations arise. The APC SL20KFB2 units are designed to kick in before the AC power drops below the operating range of the HP Superdome Enterprise Server.
Page 21
For new systems order please contact Ron Seredian at APC by e-mail at rseredia@apcc.com during the Superdome pre-consulting phase. APC will coordinate with HP to ensure the UPS is installed to meet the Superdome installation schedule. For field upgrades please contact Ron Seredian at APC by e-mail at rseredia@apcc.com...
Page 22
HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, QuickSpecs and 64-way and 64-way and 64-way and 64-way Configuration Removable media device controller should be in slot 8 of the I/O chassis.
Page 23
This is needed to allow HP-UX to boot. The customer does not need to cable is attached. This is needed to allow HP-UX to boot. The customer does not need to cable is attached.
Page 24
In the unlikely event that a CPU fails, the HP system will replace the failed CPU on the cell board at no additional charge. The iCOD CPU brings the system back to full performance and capacity levels, reducing downtime and ensuring no degradation in performance.
Page 25
In the unlikely event that a cell board fails, the HP system will replace the cell board at no additional charge. The COD cell board brings the system back to full performance and capacity levels, reducing downtime and ensuring no degradation in performance.
Page 26
This is the cornerstone of HP's pay-as-you-go Utility Pricing. Customers will be able to benefit from their servers as a "compute utility". Customers will choose when to apply additional CPU capacity and will only be charged when the additional processing power is utilized.
Page 27
64-way Upgrades This section applies to upgrades within HP Integrity Superdome systems. For information on upgrades from existing HP 9000 Superdome systems to HP Integrity Superdome systems, please refer to the upgrade section of the HP 9000 Superdome QuickSpec.
Page 28
HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, QuickSpecs and 64-way and 64-way and 64-way and 64-way Upgrades Card (A5210A) must be ordered when ordering a Superdome 32-way to 64- way upgrade.
Page 29
Quantity 1 core I/O card iCOD for Add-on and iCOD for Add-on and iCOD for Add-on and iCOD for Add-on and iCOD may be ordered on add-on cell boards, Superdome 16-way to 32-way upgrade and Superdome 32-way to Upgrades Upgrades Upgrades Upgrades 64-way upgrade.
Page 30
For CSS and BCS customers, the on site ASE collects this data. Foundation customers may choose to have HP collect the data or provide it themselves. Customer viewable documentation on extraction of this data will be available.
Page 31
HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, QuickSpecs and 64-way and 64-way and 64-way and 64-way Memory Total Total Total Total No. of No.
HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, QuickSpecs and 64-way and 64-way and 64-way and 64-way TechSpecs Superdome Specifications Superdome Specifications Superdome Specifications...
Page 33
HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, QuickSpecs and 64-way and 64-way and 64-way and 64-way TechSpecs 3-phase 5-wire input Option 6: 44 A...
Page 34
HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, QuickSpecs and 64-way and 64-way and 64-way and 64-way TechSpecs Superdome I/O Expansion Superdome I/O Expansion...
Page 35
HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, QuickSpecs and 64-way and 64-way and 64-way and 64-way TechSpecs G84Y) Units per Pallet Communications and...
Page 36
HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, QuickSpecs and 64-way and 64-way and 64-way and 64-way TechSpecs Superdome Supported I/O Superdome Supported I/O...
Page 37
HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, HP Integrity Superdome Servers: 16-way, 32-way, QuickSpecs and 64-way and 64-way and 64-way and 64-way TechSpecs Superdome Supported Online Storage Superdome Supported Online Storage...
Page 38
Each A5838A PCI 2-port 100Base-T 2-port Ultra2 SCSI card that supports a Surestore Disk System SC10 (A5272AZ) will need quantity two (2) of product number C2370A (terminator); otherwise it must have a terminated cable in place prior to HP UX boot.
Page 39
Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.