Connector/
Function
Pin Set
J1
1-3
TermPower to
SCSI Bus
J2
1-2
Reserved
3-4
Reserved
5-6
Parity Disable
7-8
Write Protect
9-10
Enable Motor
Start
11-12
Delay Motor
Start
13-14
Reserved
15-16
Reserved
17-18
Reserved
J4
1
SCSI ID 0
2
Fault LED
3
SCSI ID 1
4
Vendor unique
5
SCSI ID 2
6
Spindle Sync
7
SCSI ID 3
8
Unit Active
LED
9
Enable Term.
10
Ground
11
(+) 5 Volts
12
No connection
13-20
Reserved
8-38
SCSI and I/O
Table 8-18 A3351A Configuration Jumper Descriptions
Open: Drive does not supply term power to SCSI bus pin 26.
Jumpered: Drive supplies termination power to SCSI bus pin 26. (Default)
Leave open.
Leave open.
Open:Parity checking and reporting by the drive enabled. (Default)
Jumpered: Drive does not report the results of pairyt checking to the host.
Open: Drive is not protected (Default) .
Jumpered: Drive is write-protected.
Open:Spindle start immediately after power-up. (Default)
Jumpered: Drive spindle does not start until Start Command is received
from the host.
Open:Motor start is controlled by Enable Motor Start setting. (Default)
Jumpered: Spindle startup is delayed by SCSI ID times 12 after power is
applied.
Leave open.
Leave open.
Leave open.
Provides connerction (with Gnd, pin10) for remote SCSI ID 0 select.
Open=0.
Provides output for fault LED signal.
Provide connection (with Gnd, pin 10) for remote SCSI ID 1 select. Open=0.
Not used.
Provide connection (with Gnd, pin 10) for remote SCSI ID 2 select. Open=0.
Provides spindle sync signal SSREF oputput.
Provide connection (with Gnd, pin 10) for remote SCSI ID 3 select. Open=0.
Provides output (neg) for drive action LED
Not used on differential drives.
Provides signal for signal ground.
Provides connection for +5 volts.