See
"Master Symbol Database Size" on page 12-11.
Table 12-2 Maximum Characters for Master Symbol Database
Number of
Master Symbols
#1
#2
#3
#4
#5
Store Next Symbol Scanned as Master Symbol
After you've set the size in the database, you can order the scanner to
Definition:
store the next symbol decoded as the master symbol
<Gmaster symbol
Serial Cmd:
To store the next symbol scanned as master symbol #1 send:
<G1>. For all symbols numbers except 1, the number must be included.
Options:
1 to 10
In the
ESP:
1. Select the master symbol index number in which you want to store
the symbol data.
2. Click
The next symbol decoded will be read into the selected index.
Maximum
Characters
2045
1022
681
510
408
number>
tab in the
Master Database
Read Symbol into Selected
Number of
Master Symbols
Characters
#6
#7
#8
#9
#10
menu:
Utilities
Index.
MS-9 Scanner User's Manual
Chapter 12 Utilities
Maximum
340
291
254
226
203
<G>
or
12-13