Read Cycle Timeout

It is useful in many tightly controlled applications which require a read
Usage:
cycle to end before the next object appears and therefore need the flexi-
bility of a timeout adjustment.
Read Cycle Timeout is the time span of the read cycle and is repre-
Definition:
sented in 10 mS increments. It is used in conjunction with External
Edge or Serial Trigger.
<K220,end of read cycle
Serial Cmd:
(Corresponds to one second or 1000 mS)
Default:
100
0 to 65535. (Divide any positive number entered by 100 to determine the
Options:
time in seconds.)
Timeout does not function when in Continuous or Level read cycle modes.
Note: A minimum setting of 2 is recommended.
Continuous 1: The scanner will only read a given symbol once until a timeout occurs
or a different symbol is presented.
Note: Timeout or Timeout or New Trigger under End of Read Cycle must be
enabled for Timeout Duration to take effect.
mode,read cycle
timeout>
MS-9 Scanner User's Manual
Chapter 4 Read Cycle
4-15