High Temperature Threshold

High Temperature Threshold

A message can be defined that will display when a user-set High Temperature
Threshold has been reached. The message repeats once every 30 minutes until the
condition is corrected. This value is a reference to the external ambient temperature in
the environment around the scanner.
High Temperature Degrees
Helps ensure that the scanner is being used within its temperature speci-
Usage:
fication. Also, since hotter environments tend to shorten the life of elec-
tronics components, a user may want to set the temperature threshold
closer to the nominal temperature of 25°.
A user can set a temperature value that when exceeded will cause a high
Definition:
temperature message to be displayed. If High Temperature Threshold
is set to zero, then the warning message will be disabled
Serial Cmd:
<K402,degrees,message>
Default:
50° Celsius
0° to 50°, zero disables.
Options:
High Temperature Message
Definition:
The user can enter a message of up to 10-characters that will be dis-
played whenever High Temperature Threshold is exceeded.
<K402,degrees,message>
Serial Cmd:
Default:
HIGH_TEMP
Any 1 to 10 character ASCII string except NUL, <, or >.
Options: