Symbologies by Serial Command

Command Title
Code 39
Code 128/EAN-128
Interleaved 2 of 5
Codabar
UPC/EAN
Code 93
Pharmacode
PDF417
Narrow Margins/Symbology
ID
Background Color
Legacy
cmds
<K470,status,check digit status,check digit output status,large
Kp
intercharacter gap,fixed symbol length status,fixed symbol
length,full ASCII set>
<K474,
status,fixed symbol length status,fixed symbol
length,EAN-128 status,output format,application record separa-
Kt
tor status,application record separator character,application
record brackets,application record padding>
<K472,status,check digit status,check digit output,symbol
Kr
length #1,symbol length #2,guard bar>
<K471,status,start & stop match,start & stop output,large inter-
Kq
character gap,fixed symbol length status,fixed symbol
length,check digit type,check digit output>
<K473,
UPCstatus,EAN status,supplementals status,separa-
Ks
tor status,separator char,supplemental type>
<K475,status,fixed symbol length status,fixed symbol
K!
length>
<K477,status,fixed symbol length status,fixed symbol
length,min. no. of bars,bar widths,fwd/rev>
<K476,
status,raster sweeps before decode attempt,fixed
K[
symbol length status,fixed symbol length>
<K450,narrow margins status
Ko
<K451,
Kx
background color>
Chapter 5 Symbologies
Format
symbology identifier>
,