Specifications Torque Chart - Dodge 2000 DURANGO Service Manual

Hide thumbs Also See for 2000 DURANGO:
Table of Contents

Advertisement

25 - 34
EMISSION CONTROL SYSTEMS
REMOVAL AND INSTALLATION (Continued)
Fig. 24 Leak Detection Pump (LDP) Location
1 – BATTERY
2 – LEAK DETECTION PUMP
(LDP)
Fig. 25 LDP Filter Location
1 – LDP FILTER
2 – LDP FILTER-TO-LDP HOSE
3 – BATTERY TRAY
4 – LDP MOUNTING CLIP
(10) Remove 3 LDP mounting screws (Fig. 26) and
remove LDP from vehicle.
INSTALLATION
(1) Install LDP to bottom of battery tray. Tighten
screws to 1 N·m (11 in. lbs.) torque.
(2) Carefully install vapor/vacuum lines to LDP.
Fig. 26 Leak Detection Pump (LDP) Mounting
1 – BATTERY TRAY
2 – LDP
3 – LDP MOUNTING SCREWS (3)
The vapor/vacuum lines and hoses must be
firmly connected. Check the vapor/vacuum
lines at the LDP, LDP filter and EVAP canister
purge solenoid for damage or leaks. If a leak is
present, a Diagnostic Trouble Code (DTC) may
be set.
(3) Connect electrical connector to LDP.
(4) Install battery tray. Refer to Group 8A, Battery
for procedures.
(5) Install PDC to fender and battery tray (snaps
on to battery tray).
(6) Install LDP filter to battery tray (one clip).
(7) Install connecting hose to bottom of LDP filter.
(8) Connect battery temperature sensor pigtail
wiring harness.
(9) Install battery. Refer to Group 8A, Battery for
procedures.
(10) Connect negative battery cable to battery.
SPECIFICATIONS
TORQUE CHART
Description
EVAP Canister Mounting Nut . . . . . . . . 17–24 N·m
EVAP Canister Purge Solenoid Mounting
Bolt . . . . . . . . . . . . . . . . . . . . 11 N·m (95 in. lbs.)
Leak Detection Pump (LDP) Mounting
Screws . . . . . . . . . . . . . . . . . . 1 N·m (11 in. lbs.)
Screws
(150–210 in. lbs.)
DN
Torque

Advertisement