Remove the touch screen.
8.

Transfer belt assembly removal

1.
Open the printer front door.
Remove the transfer belt cleaner. See
2.
3.
Rotate the transfer belt lever counterclockwise to the unlock position.
Open the printhead retract door.
4.
Warning: After the photoconductor units are removed, ensure that they are properly covered so that they are
not exposed to light.
Remove the four photoconductor units.
5.
6.
Remove the transfer belt lever. See
Open the printer left duplex door assembly.
7.
Remove the fuser. See
8.