Without exiting Diagnostics mode, enter again the ATC Sensor Adjust Values to view the settings.
4
Use the ATC value conversion chart to get the corresponding Coefficient and Offset NVM values for
each barcode. See
"ATC value conversion chart" on page
menu if they match the values on the ATC value conversion chart. If the values are different, then
update the following settings to correctly match:
Settings to update
ATC SETUP COEFFICIENT (Y)
ATC SETUP COEFFICIENT (M)
ATC SETUP COEFFICIENT (C)
ATC SETUP COEFFICIENT (K)
ATC SETUP OFFSET (Y)
ATC SETUP OFFSET (M)
ATC SETUP OFFSET (C)
ATC SETUP OFFSET (K)
Touch Submit to save the settings.
Warning: The following step must be performed, or the new machine settings will not match the
5
settings listed on the birth certificate if it is required for NVM value replacement.
Retrieve the birth certificate from the compartment (1) in the media tray 1.
Using the the same Coefficient and Offset NVM values taken from step 2, overwrite the following
settings found on the birth certificate:
• ATC Setup Coefficient for Y
• ATC Setup Coefficient for M
• ATC Setup Coefficient for C
• ATC Setup Coefficient for K
• ATC Setup Offset for Y
• ATC Setup Offset for M
• ATC Setup Offset for C
• ATC Setup Offset for K
Return the birth certificate to the settings sheet compartment (1).
Exit diagnostics mode and perform a print test.
6
4-462. Check the settings shown on the
Values from the ATC value conversion chart
ATC Setup Coefficient for Y
ATC Setup Coefficient for M
ATC Setup Coefficient for C
ATC Setup Coefficient for K
ATC Setup Offset for Y
ATC Setup Offset for M
ATC Setup Offset for C
ATC Setup Offset for K
7558-xxx
1
Repair information
4-461