Step
Action and questions
Check the ADF registration motor
6
for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch ADF/SCANNER
MOTOR TESTS.
4. Touch ADF registration
motor.
Does the above component
operate properly?
Check the ADF registration motor
7
for proper connection.
Is the above component
properly connected?
Check the ADF nip release
8
solenoid for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch ADF/SCANNER
MOTOR TESTS.
4. Touch ADF nip release
solenoid.
Does the above component
operate properly?
Check the ADF nip release
9
solenoid for proper connection.
Is the above component
properly connected?
Place an undamaged document
10
in the ADF, and perform an ADF
test.
Does the error remain?
Yes
Go to step 8.
Replace the ADF registration
motor. Go to
"ADF registration
motor removal" on page
4-221.
Go to step 10.
Replace the ADF nip release
solenoid. Go to
"ADF nip
release solenoid removal" on
page
4-219.
Replace the ADF controller
PCBA. Go to
"ADF controller
PCBA removal" on page
4-206.
7558-xxx
No
Go to step 7.
Replace the connections.
Go to step 9.
Replace the connections.
Problem resolved
Diagnostic information
Previous
Next
Go Back
2-145