Test Mode - Lifting Motors - Kärcher BR 100 R Service Manual

Table of Contents

Advertisement

BR/BD 100/250 R BP / RI

5.2.3 Test mode - lifting motors

Access to
TEST-MODE
(see chapter 5.2.1)
Display
TESTER-MODE
linear actuators
>3s
Display
TESTER-MODE
linear actuators
(flashing)
Switch program switch (S9) to
Pos 1 Drive
Brush head lifting motor (M20)
Moves upwards according to the
button activation (inching mode)
until it reaches the limit position
and is switched off by:
- electronic current limiter
- microswitch (S21), provided this
function is activated in the setup
menu (Chap. 5.3).
Note:
The microswitch function can be activated/deactivated using the system menu (Chapter 5.3, brush lifting motor).
Service Manual 08.2007
Switch program switch (S9) to
Pos 2 Scrub-Vacuum
H Brush head lifting motor (M20)
Moves downwards according to the
button activation (inching mode)
until it reaches the limit position
and is switched off by:
- electronic current limiter
- microswitch (S20), provided this
function is activated in the setup
menu (Chap. 5.3).
Basic settings and service procedures
Key: Info button
Inching mode
Switch program switch (S9) to
Pos 3 Wet-Scrub
Suction beam lifting motor
(M30)
Moves upwards according to the
button activation (inching mode)
until the limit position
and is switched off by
the microswitch (S31).
Switch program switch (S9) to
Pos 4 Vacuum
H Suction beam lifting motor
(M30)
Moves downwards according
to the button activation
(inching mode)
until the limit position
and is switched off by
the microswitch (S30).