Basic settings and service procedures

5.2.2 Test mode - drive units

Program switch S9
Position No.
1
Drive
2
Scrub - vacuum
3
Wet scrubbing
4
Vacuum
5
Polish
6
Polish - vacuum
7
Empty field (manual vacuuming)
8
Empty field (Service)
Page 88 / 171
Access to
TEST-MODE
(see chapter 5.2.1)
Condition
Button
Press once
none
none
none
none
none
none
none
Sit on seat
BR/BD 100/250 R BP / RI
Display
TESTER-MODE
drives
>3s
Display
TESTER-MODE
drives
flashing
Drive units
(On/Off)
Fan - electronics compartment
(M7)
Brush motors
(M2, M3)
Suction motor
(M4)
Water pump
(M5)
Chemical pump (optional)
(M6)
Water metering valve
(Y2) (open/close)
LED-Panel
Magnetic brake
(Y2) (open/close)
Service Manual 08.2007
LED-
LED-
Service
Service
Yellow
Yellow
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off

Hide quick links: