6.2.4
Head CPU (A1) error messages
Module
Fault
classification
Forward and
reverse operation
are present at the
same time
Malfunction of
parameter buffer
Protocol error in
bus transmission
Module status
query is not
possible
Command buffer
overflow
Service Manual 08.2007
Display code
K1/163
1. Check function of travel direction switch (S2) (*)
and contact bonding.
2. Check cabling from (S2) to the module (A2) or to
module (A1) for short circuiting to the root.
3. Check correct cabling with (A2) and/or (A1).
4. If error continues, replace A2 and/or (A1).
(*) Connected to (A2) in BR/BD 100-120/250 R/I
(S2).
K1/171
1. Software error in process control -> developer:
2. Replace A1 with A1 for new firmware.
K1/172
1. Perform key switch (S0) reset several times.
2. If errors continue, test single module coupling, for
this, connect head CPU (A1) with only one ran-
K1/173
dom module as direct bus. If error is replaced by
another, test with other modules until the mal-
functioning module is found. Replace the mal-
functioning module.
3. If the error continues, inform the developer.
4. Replace (A1) with (A1) for new firmware.
K1/174
1. Perform key switch (S0) reset.
2. If fault remains, replace A1.
3. Do not activate the program switch continuously,
i.e. do not continuously perform program changes
below 1-2 seconds in the timing code!
Troubleshooting
Action
Page 143 / 171