Kärcher BR 100 R Service Manual page 145

Table of Contents

Advertisement

BR/BD 100/250 R BP / RI
6.3 Error memory
6.3.1
Module error codes – Display pattern
Display pattern of significant errors
Module description :*)
Head CPU module (A1) = 0
Drive module (A2) = 1
Cleaning module (A3), clone 1 = 2
Cleaning module (A3), clone 2 = 3
Lifting module (A4), clone 1 = 4
Lifting module (A4), clone 2 = 5
Accessories module (A5) = 6
Load module (A7) = 7
Operating hour during which
the last error occurred**)
Operating minute during
which the last error occurred**)
*)
Currently implemented module description
**)
Note: The event counter returns to 0 when the maximum value has been reached!
Display pattern of module error codes
Selected event "z"
Module description :*)
Head CPU module (A1) = 0
Drive module (A2) = 1
Cleaning module (A3), clone 1 = 2
Cleaning module (A3), clone 2 = 3
Lifting module (A4), clone 1 = 4
Lifting module (A4), clone 2 = 5
Accessories module (A5) = 6
Load module (A7) = 7
Operating hour during
which the selected event
occurred
Operating minute during
which the selected event
occurred
Module error code corre-
sponding with event "z"
Service Manual 08.2007
Module:x.y FZ zzz
21345h 02m
Module:x
t- z
10001h 45m FN: y
Troubleshooting
Error number:
5 main errors are defined
for each module (refer to
chapter 6.3.2).
Event counter, cannot be
reset.
vv
(max. of 256 events**)
*For head CPU: Internal
operating system error.
(Development info only!)
*All other modules: Module
temperature (°C) at which
the last error occurred.
Buffer of past events
New event
enters into buffer
t-0 = current event
t-1 = previous event
t-2 = ...
t-3 = ...
t-4 = ...
The oldest event is
removed from the
buffer
Storage depth of buffer:
5 events max.
Page 145 / 171

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents