Basic settings and service procedures
5.1.5.1

Accelerator pedal calibration

Requirements
– Unit is ready for service in test mode
– Program switch (S9) in Pos 5 Polish
– Above the rotary function I-button the Calibrate accelerator pedal? display is active
Display
Calibrate accelerator
pedal?
yes
Display
Release accelerator
pedal?
Do not press both pedals,
must be in the
original position
Then
Display
Floor forwards
accelerator pedal?
Fully floor pedal and hold
Then
Display
Floor accelerator
pedal backwards
Fully floor left pedal and hold
Then
Calibration o.k.?
Display
Accelerator pedal
calibration completed
3s
Page 84 / 171
no
no
no
yes
BR/BD 100/250 R BP / RI
yes
yes
Skip calibration?
no
accelerator: (663)
Difference <500
Min 683 max 688
Note:
- Switch off the key switch (S0) to quit test mode
Service Manual 08.2007