9.4.17Test the charger

Connect the charger to the batteries.
Connect the voltage meter and clip-on ammeter to
the batteries.
Plug in mains connector and switch on charger.
Determine the current and voltage measuring val-
ues after switching on the charger and record
them.
Charger data:
Appliance type:
Manufacturer
Order number of appli-
ance:
Serial number:
Purchase date:
Are damages visible on the battery?
Performance values of the charger with the battery connected immediately after the start of the charging
process (maximum, continuous current value):
Charge voltage:
Charge current (constant current!):
Performance values of the charger with the battery connected after approx. 10 minutes:
Charge voltage:
Charge current (constant current!):
Regulated charge ID line IUI charger for mainte-
nance-free batteries
Volt/Zelle
AGM / Fliesbatterie 2,4 / Gel 2,35
AGM / Fliesbatterie 2,25 / Gel 2,3
IUIa means:
I = constant current line
U = constant voltage line
I = constant current line recharging
a = automatic switch-off (transition to maintenance
charge)
The measuring result of the I constant phase in the
main charge must be close to the manufacturer's val-
ues of the charger.
See typeplate of charger.
Charge:
daily:
After each use:
Weekly:
When was the last
charge:
Ampere
I-Konstantphase U-Konstantphase
Hauptladung
Determine the current and voltage measuring val-
ues after about 10 minutes and record them.
Nachladung Erhaltungsladung
English 5.906-269.0 Rev. 00 (03/11)
Volt
Ampere
Volt
Ampere
Spannung
Strom
Zeit