Install The Radion Receiver; Install The Control Panel Enclosure; Install The Control Center - Bosch ICP-EZM2 System Reference Manual

Easy series control panel
Hide thumbs Also See for ICP-EZM2:
Table of Contents

Advertisement

26
en | System Installation and Configuration
Notice!
Refer to System Components and Wiring, page 18 throughout this section for the location to
install each of the hardware components in the enclosure.
3.2.1

Install the RADION receiver

Installing the base.
Use the provided anchors and screws to mount the receiver in locations accessible for future
maintenance. Mount the receiver onto a wall.
For best receiver reception results, place the receiver in a central location among the
transmitters. For optimal communication results in situations where there is a long distance
between the transmitting device and the system receiver, it might be necessary to install
repeaters.
Notice!
Mount the receiver in a location away from metal objects. Metal objects (duct work, wire
mesh screens, boxes) reduce RF range.
Configuring the address switch
The address switch determines the receivers numeric address value which the receiver will
use to report receiver status information to the control panel. Set the address to the receiver
prior to installation. The receiver address switches provide a single-digit setting for the
receiver's address. Address 1 and 5 are valid address settings for the receiver. All other
addresses are invalid and cause a communication error preventing the control panel from
recognizing the receiver. Use a slotted screwdriver to set the address switch.
Connecting the receiver's data bus to the control panel's data bus
Notice!
Do not install long cable runs next to high-current power feeds. Keep cable lengths as short
as possible to minimize noise pickup.
Ensure that the wiring used meets the following specifications:
Reconnect the receiver and base, and then lock the RADION receiver.
Mount the receiver temporarily in the desired location. You might need to relocate the receiver
if it does not pass RFSS testing.
3.2.2

Install the Control Panel Enclosure

1.
2.
3.
4.
3.2.3

Install the Control Center

1.
2014.09 | 01 | F.01U.306.221
Four-conductor unshielded 0.65 mm (22 AWG) to 2.0 mm (18 AWG) maximum.
Wire length must not exceed 243 m (800 ft) from the control panel
Remove the desired knockouts from the control panel enclosure and optional mounting
skirt.
Attach the optional mounting skirt to the enclosure.
Route the wires through the desired knockouts.
Mount the enclosure to the desired surface. Use proper anchor and screw sets when you
install the enclosure on non-load-bearing surfaces, such as drywall.
Unlock the control center and separate it from the base.