Rps Configuration Items; Route Reporting Options - Bosch ICP-EZM2 System Reference Manual

Easy series control panel
Hide thumbs Also See for ICP-EZM2:
Table of Contents

Advertisement

54
en | Programming
5.2.4

RPS Configuration Items

Programming Item
RPS Passcode
RPS Automatic Call In Frequency
RPS Automatic Call In Time (Hours) 225
RPS Automatic Call in Time
(Minutes)
RPS Automatic Call in Time (Day of
Week)
RPS Automatic Call in Time (Day of
Month)
RPS Automatic Call in Phone
Number
RPS Automatic Call in Method
RPS Port Number
5.2.5

Route Reporting Options

Point Report and Restoral Routing
Programming Item
Point Reports and Restorals (all)*
Intrusion Alarm
Intrusion Alarm Verified
2014.09 | 01 | F.01U.306.221
Item
Selections
Number
118
6 digits, using 0 to 9 and A to F.
224
0 = Never
1 = Daily
2 = Weekly
3 = Monthly
0 to 23
226
0 to 59
227
0 to 6, where 0 = Sunday and 6 = Saturday
228
1 to 28
229
Enter a phone number (up to 32 digits) or IP address
(000.000.000.000 to 255.255.255.255) for each
destination:
0 to 9 = [0] to [9]
* = [*][*]
# = [*][#]
Pause = [*][1]
Exit with save = [#]
Exit without save = [#][#]
Press [#] twice within two seconds to exit without
saving your entry.
Disable phone number = [0][#]
Disable IP address = 240.0.0.0
245
0 = Phone number
1 = IP address
246
0 to 65535
Item
Manuf.
Programming Item
Numbe
Default
r
301
3
Fire Trouble
307
3
Fire Trouble Restoral
308
3
24-Hour Trouble
System Reference Guide
Easy Series Control Panel
Manuf.
Defaul
t
12345
6
7750
Item
Manuf.
Numbe
Default
r
328
3
329
3
331
3
Bosch Security Systems, Inc.