en | Device Specifications and Overview
Device testing
Temperature (operating)
Relative humidity
Wall tamper switch
Frequency
Table 8.16: Specifications
Dual EOL Resistor Option
Use a 2.2 kᅳΩ and 1.5 kᅳΩ EOL resistor. Refer to the following figure.
Figure 8.10: Dual EOL resistor options
1 ᅳ Normally-closed (NC) alarm
2 ᅳ Normally-closed (NC) tamper
3 ᅳ 1.5 k Ω alarm EOL
4 ᅳ 2.2 k Ω tamper EOL
Notice!
To disable the alarm input, insert the EOL resistor directly into the inertia terminal block,
minus wiring to external devices.
8.16.1

Installation considerations

You have a variety of installation options to consider when installing the device. You must
acknowledge the unique installation approach prior to installation. Some installation
considerations include:
2014.09 | 01 | F.01U.306.221
1
3
2
Suitable surfaces for installation include wood, steel, and aluminum.
System Reference Guide
To ensure proper functionality, the device must be
tested at least once every year.
0゚C to +49゚C (+32゚F to +120゚F)
0% to 93% (non-condensing)
Transmits a tamper signal when someone removes the
device from its base or pulls it away from the wall.
433.42 MHz