Reed Switch Settings; Radion Inertia - Bosch ICP-EZM2 System Reference Manual

Easy series control panel
Hide thumbs Also See for ICP-EZM2:
Table of Contents

Advertisement

Easy Series Control Panel
Notice!
The content in the graphical table applies to EN installations.
8.15.2

Reed switch settings

Set the detector to enable or disable the reed switch.
Notice!
Please note, insert the jumper onto the pin prior to installing the battery. Failure to do so may
result in unexpected operation of the device.
Callout ᅳ Description
1 ᅳ No jumper disables the internal reed switch
2 ᅳ Jumper on enables the internal reed switch
8.16

RADION inertia

The RFIN is a vibration detector combined with a wireless transceiver used for monitoring
doors or windows. Features include:
Maximum distance between
detector and magnet
Dimensions (transmitter)
Dimensions (magnet)
Power/voltage
Battery replacement
Bosch Security Systems, Inc.
A magnetic contact and external loop
High and Low sensitivity settings
Gross and Minor attack settings
A cover and wall tamper switch
System Reference Guide
Device Specifications and Overview | en
<12.7 mm (1/2 in)
Place the magnet on either side of the detector.
22 mm x 91 mm x 35 mm
(0.87 in x 3.20 in x 1.38 in)
22 mm x 28 mm x 15 mm
(0.87 in x 1.10 in x .59 in)
CR123A Lithium battery, 3 VDC (
One Duracell DL123A, or Panasonic CR123A, or Sanyo
CR123A. Check your battery yearly to ensure proper
functionality.
97
)
2014.09 | 01 | F.01U.306.221