RADION contact SM

The RFDW-SM is a standard surface-mount wireless transmitter device used for monitoring
doors and windows.
Features include:
Power/voltage
Battery replacement
Battery life
Device testing
Dimensions (transmitter)
Dimensions (magnet)
Temperature (operating)
Relative humidity
Wall and Cover Tamper Switch
Frequency
Table 8.12: Specifications
8.12.1

Installation considerations

You have a variety of installation options to consider when installing the device. You must
acknowledge the unique installation approach prior to installation. Some installation
considerations include:
Bosch Security Systems, Inc.
An internal reed switch
A cover and wall tamper switch
Suitable surfaces for installation include wood, steel, and aluminum.
The location of the magnet and transmitter in relationship to the door/window frame
dimensions. Verify you have proper clearance with the latch of the window or door you
are installing the device onto. Failure to do so will make it extremely difficult to access
and open the device for maintenance purposes.
In some cases, you might need an additional spacer when installing the transmitter and
magnet in the corner of a recessed door or window frame to close the gap in height
between the magnet and transmitter.
For additional security, you can use an adhesive with the screws to secure the
transmitters and magnets during installation.
System Reference Guide
Device Specifications and Overview | en
One AAA Lithium battery, 1.5 VDC (
Power source type: C
Low battery level: 0.9V
Energizer L92. Check your battery yearly to ensure
proper functionality.
Up to 5 years
To ensure proper functionality, the device must be tested
at least once every year by an installer.
19.50 mm x 82.55 mm x 12.80 mm
(0.76 in x 3.25 in x 0.50 in)
24.5 mm x 18.5 mm x 12.5 mm
(0.97 in x 0.72 in x 0.49 in)
Functional range: -10°C to +49°C (+14°F to +120°F)
EN 50130-5 Class II only: -10゚C to 40゚C (+14゚F to +104゚
F)
0% to 93% (non-condensing)
Transmits a tamper signal when someone removes the
device from its base or pulls it away from the wall.
433.42 MHz