Bosch ICP-EZM2 System Reference Manual page 50

Easy series control panel
Hide thumbs Also See for ICP-EZM2:
Table of Contents

Advertisement

50
en | Programming
Programming Item
Test Report Minute
Test Report Day of Week
Test Report Day of Month
Clear Confirmed Alarm Memory
Arming Beeps/Graduated
Annunciation
Wireless Jam Detect Level
Wireless Device Supervision Interval
Key Fob Arming
Two-Way Voice Session
Configuration
Start Arming with Faulted Points
Speak Active Faults
Wireless Transmission Attenuation
2014.09 | 01 | F.01U.306.221
Item
Selections
Number
144
0 to 59
145
0 to 6, where 0 = Sunday and 6 = Saturday
146
1 to 28
147
0 = User can clear a confirmed alarm
1 = Only the installer can clear a confirmed alarm
148
0 = No arming beeps or outputs during Entry Delay
1 = Outputs activate during Entry Delay, but no
arming beeps occur.
2 = Sound arming beeps, but outputs do not
activate during Entry Delay
3 = Sound arming beeps, and outputs activate
during Entry Delay
150
0 to 15
151
1= 1 Hour
2= 2 Hours
3= 4 Hours
4= 12 Hours
5= 24Hours
6= 2.5 Hours
153
0 = Do not turn system on if there are faulted
points
1 = Force arm faulted points if the number of
faulted points is within the range set in Expert
Programming Item Number 125
2 = Force arm faulted points even if the number of
faulted points exceeds the range set in Expert
Programming Item Number 125
158
0 = Allow at any time
1 = Allow only during alarm conditions
159
0 = Force arm all faulted points
1 = Exit Delay starts with faulted points
160
0 = "Call for Service" announced
1 = Fault condition announced
161
Temporary attenuation for installation and
maintenance only. Not intended for normal
operation.
0 = None (normal operation)
1 = 3 dB
2 = 6 dB
3 = 9 dB
4 = 12 dB
System Reference Guide
Easy Series Control Panel
Manuf.
Default
0
0
1
0
0
12
0
0
1
0
0
Bosch Security Systems, Inc.

Advertisement