en | Agency Approvals and Requirements
(Autre)
Total aux current: C
Total A + B + C
Max backup current available, with a 17 AH battery
(type 2, 36H)
Current chart of the Aux power supply IPP-PSU-2A5
When the current required by additional components is higher than the backup current
available from the control panel with the 17AH battery, add one or several auxiliary power
supply IPP-PSU-2A5.
The IPP-PSU-2A5 provides also the 14.5V output required by the siren batteries.
Module
IPP-PSU-2A5
Detector(s)
Siren(s)
Control center(s)
Total aux current: C
Total in Idle State
Max backup current available, with a 17 AH battery
The IPP-PSU-2A5 auxiliary power supply provides a protection against the deep discharge of the battery (active at
idle state) and status LEDs. This current has to be taken into account in the current chart.
Max. available current in idle state: 465 mA.
Max. current in alarm: 750 mA.
Notice!
For Aux power supply supervision, use an input from the control panel or from a DX2010,
with a two resistors wiring (alarm and tamper)
Connect the output relay "trouble" from the aux power supply to a 24hr/24hr input. Record
the zone name with a text meaning "AC loss aux power supply"
On the tamper zone, connect the tamper contact of the aux power supply enclosure
Controller Recorder Wiring
To connect a controller / recorder, connect the coil input of the recorder to + and - of PO2,
PO3 and/or PO4.
Set the output as follows:
Programming Items
To comply with NF A2P, set these programming items as follows:
2014.09 | 01 | F.01U.306.221
x Qty
Max Current in Idle State
I Max
55 mA
x1
x Qty
x Qty
x Qty
To record the state "arm unoccupied", set the output to "armed unoccupied"
To record the state "alarm", set the corresponding output to "intrusion and fire 2"
(reversed level)
System Reference Guide
...mA
...mA
465 mA
Max Current In Alarm State
Total
I Max
55 mA
55 mA
...mA
...mA
Total in alarm state
465 mA
Easy Series Control Panel
x Qty
...mA
...mA
1000 mA
Total
x1
55 mA
xQty
x Qty
x Qty
...mA
...mA
750 mA